This is a cache of https://docs.openshift.com/container-platform/4.15/windows_containers/enabling-windows-container-workloads.html. It is a snapshot of the page at 2024-11-24T12:27:59.483+0000.
<strong>e</strong>nabling Windows contain<strong>e</strong>r workloads | Windows Contain<strong>e</strong>r Support for Op<strong>e</strong>nShift | Op<strong>e</strong>nShift Contain<strong>e</strong>r Platform 4.15
&times;

Before adding Windows workloads to your cluster, you must install the Windows Machine Config Operator (WMCO), which is available in the OpenShift Container Platform OperatorHub. The WMCO orchestrates the process of deploying and managing Windows workloads on a cluster.

Dual NIC is not supported on WMCO-managed Windows instances.

Prerequisites

  • You have access to an OpenShift Container Platform cluster using an account with cluster-admin permissions.

  • You have installed the OpenShift CLI (oc).

  • You have installed your cluster using installer-provisioned infrastructure, or using user-provisioned infrastructure with the platform: none field set in your install-config.yaml file.

  • You have configured hybrid networking with OVN-Kubernetes for your cluster. For more information, see Configuring hybrid networking.

  • You are running an OpenShift Container Platform cluster version 4.6.8 or later.

Windows instances deployed by the WMCO are configured with the containerd container runtime. Because WMCO installs and manages the runtime, it is recommanded that you do not manually install containerd on nodes.

Additional resources

Installing the Windows Machine Config Operator

You can install the Windows Machine Config Operator using either the web console or OpenShift CLI (oc).

Due to a limitation within the Windows operating system, clusterNetwork CIDR addresses of class e, such as 240.0.0.0, are not compatible with Windows nodes.

Installing the Windows Machine Config Operator using the web console

You can use the OpenShift Container Platform web console to install the Windows Machine Config Operator (WMCO).

Dual NIC is not supported on WMCO-managed Windows instances.

Procedure
  1. From the Administrator perspective in the OpenShift Container Platform web console, navigate to the Operators → OperatorHub page.

  2. Use the Filter by keyword box to search for Windows Machine Config Operator in the catalog. Click the Windows Machine Config Operator tile.

  3. Review the information about the Operator and click Install.

  4. On the Install Operator page:

    1. Select the stable channel as the Update Channel. The stable channel enables the latest stable release of the WMCO to be installed.

    2. The Installation Mode is preconfigured because the WMCO must be available in a single namespace only.

    3. Choose the Installed Namespace for the WMCO. The default Operator recommended namespace is openshift-windows-machine-config-operator.

    4. Click the enable Operator recommended cluster monitoring on the Namespace checkbox to enable cluster monitoring for the WMCO.

    5. Select an Approval Strategy.

      • The Automatic strategy allows Operator Lifecycle Manager (OLM) to automatically update the Operator when a new version is available.

      • The Manual strategy requires a user with appropriate credentials to approve the Operator update.

  1. Click Install. The WMCO is now listed on the Installed Operators page.

    The WMCO is installed automatically into the namespace you defined, like openshift-windows-machine-config-operator.

  2. Verify that the Status shows Succeeded to confirm successful installation of the WMCO.

Installing the Windows Machine Config Operator using the CLI

You can use the OpenShift CLI (oc) to install the Windows Machine Config Operator (WMCO).

Dual NIC is not supported on WMCO-managed Windows instances.

Procedure
  1. Create a namespace for the WMCO.

    1. Create a Namespace object YAML file for the WMCO. For example, wmco-namespace.yaml:

      apiVersion: v1
      kind: Namespace
      metadata:
        name: openshift-windows-machine-config-operator (1)
        labels:
          openshift.io/cluster-monitoring: "true" (2)
      1 It is recommended to deploy the WMCO in the openshift-windows-machine-config-operator namespace.
      2 This label is required for enabling cluster monitoring for the WMCO.
    2. Create the namespace:

      $ oc create -f <file-name>.yaml

      For example:

      $ oc create -f wmco-namespace.yaml
  2. Create the Operator group for the WMCO.

    1. Create an OperatorGroup object YAML file. For example, wmco-og.yaml:

      apiVersion: operators.coreos.com/v1
      kind: OperatorGroup
      metadata:
        name: windows-machine-config-operator
        namespace: openshift-windows-machine-config-operator
      spec:
        targetNamespaces:
        - openshift-windows-machine-config-operator
    2. Create the Operator group:

      $ oc create -f <file-name>.yaml

      For example:

      $ oc create -f wmco-og.yaml
  3. Subscribe the namespace to the WMCO.

    1. Create a Subscription object YAML file. For example, wmco-sub.yaml:

      apiVersion: operators.coreos.com/v1alpha1
      kind: Subscription
      metadata:
        name: windows-machine-config-operator
        namespace: openshift-windows-machine-config-operator
      spec:
        channel: "stable" (1)
        installPlanApproval: "Automatic" (2)
        name: "windows-machine-config-operator"
        source: "redhat-operators" (3)
        sourceNamespace: "openshift-marketplace" (4)
      1 Specify stable as the channel.
      2 Set an approval strategy. You can set Automatic or Manual.
      3 Specify the redhat-operators catalog source, which contains the windows-machine-config-operator package manifests. If your OpenShift Container Platform is installed on a restricted network, also known as a disconnected cluster, specify the name of the CatalogSource object you created when you configured the Operator LifeCycle Manager (OLM).
      4 Namespace of the catalog source. Use openshift-marketplace for the default OperatorHub catalog sources.
    2. Create the subscription:

      $ oc create -f <file-name>.yaml

      For example:

      $ oc create -f wmco-sub.yaml

      The WMCO is now installed to the openshift-windows-machine-config-operator.

  4. Verify the WMCO installation:

    $ oc get csv -n openshift-windows-machine-config-operator
    example output
    NAMe                                    DISPLAY                           VeRSION   RePLACeS   PHASe
    windows-machine-config-operator.2.0.0   Windows Machine Config Operator   2.0.0                Succeeded

Configuring a secret for the Windows Machine Config Operator

To run the Windows Machine Config Operator (WMCO), you must create a secret in the WMCO namespace containing a private key. This is required to allow the WMCO to communicate with the Windows virtual machine (VM).

Prerequisites
  • You installed the Windows Machine Config Operator (WMCO) using Operator Lifecycle Manager (OLM).

  • You created a PeM-encoded file containing an RSA key.

Procedure
  • Define the secret required to access the Windows VMs:

    $ oc create secret generic cloud-private-key --from-file=private-key.pem=${HOMe}/.ssh/<key> \
        -n openshift-windows-machine-config-operator (1)
1 You must create the private key in the WMCO namespace, like openshift-windows-machine-config-operator.

It is recommended to use a different private key than the one used when installing the cluster.

Using Windows containers in a proxy-enabled cluster

The Windows Machine Config Operator (WMCO) can consume and use a cluster-wide egress proxy configuration when making external requests outside the cluster’s internal network.

This allows you to add Windows nodes and run workloads in a proxy-enabled cluster, allowing your Windows nodes to pull images from registries that are secured behind your proxy server or to make requests to off-cluster services and services that use a custom public key infrastructure.

The cluster-wide proxy affects system components only, not user workloads.

In proxy-enabled clusters, the WMCO is aware of the NO_PROXY, HTTP_PROXY, and HTTPS_PROXY values that are set for the cluster. The WMCO periodically checks whether the proxy environment variables have changed. If there is a discrepancy, the WMCO reconciles and updates the proxy environment variables on the Windows instances.

Windows workloads created on Windows nodes in proxy-enabled clusters do not inherit proxy settings from the node by default, the same as with Linux nodes. Also, by default PowerShell sessions do not inherit proxy settings on Windows nodes in proxy-enabled clusters.

Additional resources

Rebooting a node gracefully

The Windows Machine Config Operator (WMCO) minimizes node reboots whenever possible. However, certain operations and updates require a reboot to ensure that changes are applied correctly and securely. To safely reboot your Windows nodes, use the graceful reboot process. For information on gracefully rebooting a standard OpenShift Container Platform node, see "Rebooting a node gracefully" in the Nodes documentation.

Before rebooting a node, it is recommended to backup etcd data to avoid any data loss on the node.

For single-node OpenShift clusters that require users to perform the oc login command rather than having the certificates in kubeconfig file to manage the cluster, the oc adm commands might not be available after cordoning and draining the node. This is because the openshift-oauth-apiserver pod is not running due to the cordon. You can use SSH to access the nodes as indicated in the following procedure.

In a single-node OpenShift cluster, pods cannot be rescheduled when cordoning and draining. However, doing so gives the pods, especially your workload pods, time to properly stop and release associated resources.

Procedure

To perform a graceful restart of a node:

  1. Mark the node as unschedulable:

    $ oc adm cordon <node1>
  2. Drain the node to remove all the running pods:

    $ oc adm drain <node1> --ignore-daemonsets --delete-emptydir-data --force

    You might receive errors that pods associated with custom pod disruption budgets (PDB) cannot be evicted.

    example error
    error when evicting pods/"rails-postgresql-example-1-72v2w" -n "rails" (will retry after 5s): Cannot evict pod as it would violate the pod's disruption budget.

    In this case, run the drain command again, adding the disable-eviction flag, which bypasses the PDB checks:

    $ oc adm drain <node1> --ignore-daemonsets --delete-emptydir-data --force --disable-eviction
  3. SSH into the Windows node and enter PowerShell by running the following command:

    C:\> powershell
  4. Restart the node by running the following command:

    C:\>  Restart-Computer -Force
  5. Windows nodes on Amazon Web Services (AWS) do not return to ReADY state after a graceful reboot due to an inconsistency with the eC2 instance metadata routes and the Host Network Service (HNS) networks.

    After the reboot, SSH into any Windows node on AWS and add the route by running the following command in a shell prompt:

    C:\> route add 169.254.169.254 mask 255.255.255.0 <gateway_ip>

    where:

    169.254.169.254

    Specifies the address of the eC2 instance metadata endpoint.

    255.255.255.255

    Specifies the network mask of the eC2 instance metadata endpoint.

    <gateway_ip>

    Specifies the corresponding IP address of the gateway in the Windows instance, which you can find by running the following command:

    C:\> ipconfig | findstr /C:"Default Gateway"
  6. After the reboot is complete, mark the node as schedulable by running the following command:

    $ oc adm uncordon <node1>
  7. Verify that the node is ready:

    $ oc get node <node1>
    example output
    NAMe    STATUS  ROLeS    AGe     VeRSION
    <node1> Ready   worker   6d22h   v1.18.3+b0068a8