<cluster-name>.<domain-name>
Installer-provisioned installation of OKD requires:
One provisioner node with Fedora CoreOS (FCOS) installed.
Three control plane nodes.
Baseboard Management Controller (BMC) access to each node.
At least one network:
One required routable network
One optional network for provisioning nodes; and,
One optional management network.
Before starting an installer-provisioned installation of OKD, ensure the hardware environment meets the following requirements.
Installer-provisioned installation involves a number of hardware node requirements:
CPU architecture: All nodes must use x86_64
CPU architecture.
Similar nodes: Red Hat recommends nodes have an identical configuration per role. That is, Red Hat recommends nodes be the same brand and model with the same CPU, memory, and storage configuration.
Baseboard Management Controller: The provisioner
node must be able to access the baseboard management controller (BMC) of each OKD cluster node. You may use IPMI, RedFish, or a proprietary protocol.
Latest generation: Nodes must be of the most recent generation. Because the installer-provisioned installation relies on BMC protocols, the hardware must support IPMI cipher suite 17. Additionally, Fedora CoreOS (FCOS) ships with the most recent drivers for RAID controllers. Ensure that the nodes are recent enough to support FCOS for the provisioner
node and FCOS for the control plane and worker nodes.
Registry node: Optional: If setting up a disconnected mirrored registry, it is recommended the registry reside in its own node.
Provisioner node: Installer-provisioned installation requires one provisioner
node.
Control plane: Installer-provisioned installation requires three control plane nodes for high availability.
Worker nodes: While not required, a typical production cluster has one or more worker nodes. Smaller clusters are more resource efficient for administrators and developers during development and testing.
Network interfaces: Each node must have at least one network interface for the routable baremetal
network. Each node must have one network interface for a provisioning
network when using the provisioning
network for deployment. Using the provisioning
network is the default configuration. Network interface naming must be consistent across control plane nodes for the provisioning network. For example, if a control plane node uses the eth0
NIC for the provisioning network, the other control plane nodes must use it as well.
Unified Extensible Firmware Interface (UEFI): Installer-provisioned installation requires UEFI boot on all OKD nodes when using IPv6 addressing on the provisioning
network. In addition, UEFI Device PXE Settings must be set to use the IPv6 protocol on the provisioning
network NIC, but omitting the provisioning
network removes this requirement.
Installer-provisioned installation of OKD involves several network requirements by default. First, installer-provisioned installation involves a non-routable provisioning
network for provisioning the operating system on each bare metal node and a routable baremetal
network. Since installer-provisioned installation deploys ironic-dnsmasq
, the networks should have no other DHCP servers running on the same broadcast domain. Network administrators must reserve IP addresses for each node in the OKD cluster.
It is recommended that each OKD node in the cluster have access to a Network Time Protocol (NTP) server that is discoverable using DHCP. While installation without an NTP server is possible, asynchronous server clocks can cause errors. Using an NTP server can prevent this issue.
OKD deploys with two networks:
provisioning
: The provisioning
network is an optional non-routable network used for provisioning the underlying operating system on each node that is a part of the OKD cluster. When deploying using the provisioning
network, the first NIC on each node, such as eth0
or eno1
,
must interface with the provisioning
network.
baremetal
: The baremetal
network is a routable network. When deploying using the provisioning
network, the second NIC on each node, such as eth1
or eno2
, must interface with the baremetal
network. When deploying without a provisioning
network, you can use any NIC on each node to interface with the baremetal
network.
Each NIC should be on a separate VLAN corresponding to the appropriate network. |
Clients access the OKD cluster nodes over the baremetal
network.
A network administrator must configure a subdomain or subzone where the canonical name extension is the cluster name.
<cluster-name>.<domain-name>
For example:
test-cluster.example.com
For the baremetal
network, a network administrator must reserve a number of IP addresses, including:
Two virtual IP addresses.
One IP address for the API endpoint
One IP address for the wildcard ingress endpoint
One IP address for the provisioner node.
One IP address for each control plane (master) node.
One IP address for each worker node, if applicable.
The following table provides an exemplary embodiment of fully-qualified domain names. The API and Nameserver addresses begin with canonical name extensions. The hostnames of the control plane and worker nodes are exemplary, so you can use any host naming convention you prefer.
Usage | Hostname | IP |
---|---|---|
API |
api.<cluster-name>.<domain> |
<ip> |
ingress LB (apps) |
*.apps.<cluster-name>.<domain> |
<ip> |
Provisioner node |
provisioner.<cluster-name>.<domain> |
<ip> |
Master-0 |
openshift-master-0.<cluster-name>.<domain> |
<ip> |
Master-1 |
openshift-master-1.<cluster-name>-.<domain> |
<ip> |
Master-2 |
openshift-master-2.<cluster-name>.<domain> |
<ip> |
Worker-0 |
openshift-worker-0.<cluster-name>.<domain> |
<ip> |
Worker-1 |
openshift-worker-1.<cluster-name>.<domain> |
<ip> |
Worker-n |
openshift-worker-n.<cluster-name>.<domain> |
<ip> |
All installer-provisioned installations require a baremetal
network. The baremetal
network is a routable network used for external network access to the outside world. In addition to the IP address supplied to the OKD cluster node, installations without a provisioning
network require the following:
Setting an available IP address from the baremetal
network to the bootstrapProvisioningIP
configuration setting within the install-config.yaml
configuration file.
Setting an available IP address from the baremetal
network to the provisioningHostIP
configuration setting within the install-config.yaml
configuration file.
Deploying the OKD cluster using RedFish Virtual Media/iDRAC Virtual Media.
Configuring additional IP addresses for |
The out-of-band management IP address is on a separate network from the node. To ensure that the out-of-band management can communicate with the baremetal
node during installation, the out-of-band management IP address address must be granted access to the TCP 6180 port.
provisioning
networkEach node in the cluster requires the following configuration for proper installation.
A mismatch between nodes will cause an installation failure. |
While the cluster nodes can contain more than two NICs, the installation process only focuses on the first two NICs:
NIC |
Network |
VLAN |
NIC1 |
|
<provisioning-vlan> |
NIC2 |
|
<baremetal-vlan> |
NIC1 is a non-routable network (provisioning
) that is only used for the installation of the OKD cluster.
The Fedora CoreOS (FCOS) installation process on the provisioner node might vary. To install FCOS using a local Satellite server or a PXE server, PXE-enable NIC2.
PXE |
Boot order |
NIC1 PXE-enabled |
1 |
NIC2 |
2 |
Ensure PXE is disabled on all other NICs. |
Configure the control plane and worker nodes as follows:
PXE |
Boot order |
NIC1 PXE-enabled (provisioning network) |
1 |
provisioning
networkThe installation process requires one NIC:
NIC |
Network |
VLAN |
NICx |
|
<baremetal-vlan> |
NICx is a routable network (baremetal
) that is used for the installation of the OKD cluster, and routable to the Internet.
Nodes will typically have an additional NIC used by the Baseboard Management Controllers (BMCs). These BMCs must be accessible from the provisioner
node.
Each node must be accessible via out-of-band management. When using an out-of-band management network, the provisioner
node requires access to the out-of-band management network for a successful OKD 4 installation.
The out-of-band management setup is out of scope for this document. We recommend setting up a separate management network for out-of-band management. However, using the provisioning
network or the baremetal
network are valid options.
Prior to the installation of the OKD cluster, gather the following information from all cluster nodes:
Out-of-band management IP
Examples
Dell (iDRAC) IP
HP (iLO) IP
provisioning
networkNIC1 (provisioning
) MAC address
NIC2 (baremetal
) MAC address
provisioning
networkNICx (baremetal
) MAC address
provisioning
network NIC1 VLAN is configured for the provisioning
network.
NIC2 VLAN is configured for the baremetal
network.
NIC1 is PXE-enabled on the provisioner, control plane (master), and worker nodes.
PXE has been disabled on all other NICs.
Control plane and worker nodes are configured.
All nodes accessible via out-of-band management.
A separate management network has been created. (optional)
Required data for installation.
provisioning
network NICx VLAN is configured for the baremetal
network.
Control plane and worker nodes are configured.
All nodes accessible via out-of-band management.
A separate management network has been created. (optional)
Required data for installation.