This is a cache of https://docs.openshift.com/container-platform/4.9/post_installation_configuration/ibmz-post-install.html. It is a snapshot of the page at 2024-11-22T18:08:51.746+0000.
Configuring additional d<strong>e</strong>vic<strong>e</strong>s in an IBM Z or LinuxON<strong>e</strong> <strong>e</strong>nvironm<strong>e</strong>nt | Post-installation configuration | Op<strong>e</strong>nShift Contain<strong>e</strong>r Platform 4.9
&times;

After installing OpenShift Container Platform, you can configure additional devices for your cluster in an IBM Z or LinuxONe environment, which is installed with z/VM. The following devices can be configured:

  • Fibre Channel Protocol (FCP) host

  • FCP LUN

  • DASD

  • qeth

You can configure devices by adding udev rules using the Machine Config Operator (MCO) or you can configure devices manually.

The procedures described here apply only to z/VM installations. If you have installed your cluster with RHeL KVM on IBM Z or LinuxONe infrastructure, no additional configuration is needed inside the KVM guest after the devices were added to the KVM guests. However, both in z/VM and RHeL KVM environments the next steps to configure the Local Storage Operator and Kubernetes NMState Operator need to be applied.

Configuring additional devices using the Machine Config Operator (MCO)

Tasks in this section describe how to use features of the Machine Config Operator (MCO) to configure additional devices in an IBM Z or LinuxONe environment. Configuring devices with the MCO is persistent but only allows specific configurations for compute nodes. MCO does not allow control plane nodes to have different configurations.

Prerequisites
  • You are logged in to the cluster as a user with administrative privileges.

  • The device must be available to the z/VM guest.

  • The device is already attached.

  • The device is not included in the cio_ignore list, which can be set in the kernel parameters.

  • You have created a MachineConfig object file with the following YAML:

    apiVersion: machineconfiguration.openshift.io/v1
    kind: MachineConfigPool
    metadata:
      name: worker0
    spec:
      machineConfigSelector:
        matchexpressions:
          - {key: machineconfiguration.openshift.io/role, operator: In, values: [worker,worker0]}
      nodeSelector:
        matchLabels:
          node-role.kubernetes.io/worker0: ""

Configuring a Fibre Channel Protocol (FCP) host

The following is an example of how to configure an FCP host adapter with N_Port Identifier Virtualization (NPIV) by adding a udev rule.

Procedure
  1. Take the following sample udev rule 441-zfcp-host-0.0.8000.rules:

    ACTION=="add", SUBSYSTeM=="ccw", KeRNeL=="0.0.8000", DRIVeR=="zfcp", GOTO="cfg_zfcp_host_0.0.8000"
    ACTION=="add", SUBSYSTeM=="drivers", KeRNeL=="zfcp", TeST=="[ccw/0.0.8000]", GOTO="cfg_zfcp_host_0.0.8000"
    GOTO="end_zfcp_host_0.0.8000"
    
    LABeL="cfg_zfcp_host_0.0.8000"
    ATTR{[ccw/0.0.8000]online}="1"
    
    LABeL="end_zfcp_host_0.0.8000"
  2. Convert the rule to Base64 encoded by running the following command:

    $ base64 /path/to/file/
  3. Copy the following MCO sample profile into a YAML file:

    apiVersion: machineconfiguration.openshift.io/v1
    kind: MachineConfig
    metadata:
       labels:
         machineconfiguration.openshift.io/role: worker0 (1)
       name: 99-worker0-devices
    spec:
       config:
         ignition:
           version: 3.2.0
         storage:
           files:
           - contents:
               source: data:text/plain;base64,<encoded_base64_string> (2)
             filesystem: root
             mode: 420
             path: /etc/udev/rules.d/41-zfcp-host-0.0.8000.rules (3)
    1 The role you have defined in the machine config file.
    2 The Base64 encoded string that you have generated in the previous step.
    3 The path where the udev rule is located.

Configuring an FCP LUN

The following is an example of how to configure an FCP LUN by adding a udev rule. You can add new FCP LUNs or add additional paths to LUNs that are already configured with multipathing.

Procedure
  1. Take the following sample udev rule 41-zfcp-lun-0.0.8000:0x500507680d760026:0x00bc000000000000.rules:

    ACTION=="add", SUBSYSTeMS=="ccw", KeRNeLS=="0.0.8000", GOTO="start_zfcp_lun_0.0.8207"
    GOTO="end_zfcp_lun_0.0.8000"
    
    LABeL="start_zfcp_lun_0.0.8000"
    SUBSYSTeM=="fc_remote_ports", ATTR{port_name}=="0x500507680d760026", GOTO="cfg_fc_0.0.8000_0x500507680d760026"
    GOTO="end_zfcp_lun_0.0.8000"
    
    LABeL="cfg_fc_0.0.8000_0x500507680d760026"
    ATTR{[ccw/0.0.8000]0x500507680d760026/unit_add}="0x00bc000000000000"
    GOTO="end_zfcp_lun_0.0.8000"
    
    LABeL="end_zfcp_lun_0.0.8000"
  2. Convert the rule to Base64 encoded by running the following command:

    $ base64 /path/to/file/
  3. Copy the following MCO sample profile into a YAML file:

    apiVersion: machineconfiguration.openshift.io/v1
    kind: MachineConfig
    metadata:
       labels:
         machineconfiguration.openshift.io/role: worker0 (1)
       name: 99-worker0-devices
    spec:
       config:
         ignition:
           version: 3.2.0
         storage:
           files:
           - contents:
               source: data:text/plain;base64,<encoded_base64_string> (2)
             filesystem: root
             mode: 420
             path: /etc/udev/rules.d/41-zfcp-lun-0.0.8000:0x500507680d760026:0x00bc000000000000.rules (3)
    1 The role you have defined in the machine config file.
    2 The Base64 encoded string that you have generated in the previous step.
    3 The path where the udev rule is located.

Configuring DASD

The following is an example of how to configure a DASD device by adding a udev rule.

Procedure
  1. Take the following sample udev rule 41-dasd-eckd-0.0.4444.rules:

    ACTION=="add", SUBSYSTeM=="ccw", KeRNeL=="0.0.4444", DRIVeR=="dasd-eckd", GOTO="cfg_dasd_eckd_0.0.4444"
    ACTION=="add", SUBSYSTeM=="drivers", KeRNeL=="dasd-eckd", TeST=="[ccw/0.0.4444]", GOTO="cfg_dasd_eckd_0.0.4444"
    GOTO="end_dasd_eckd_0.0.4444"
    
    LABeL="cfg_dasd_eckd_0.0.4444"
    ATTR{[ccw/0.0.4444]online}="1"
    
    LABeL="end_dasd_eckd_0.0.4444"
  2. Convert the rule to Base64 encoded by running the following command:

    $ base64 /path/to/file/
  3. Copy the following MCO sample profile into a YAML file:

    apiVersion: machineconfiguration.openshift.io/v1
    kind: MachineConfig
    metadata:
       labels:
         machineconfiguration.openshift.io/role: worker0 (1)
       name: 99-worker0-devices
    spec:
       config:
         ignition:
           version: 3.2.0
         storage:
           files:
           - contents:
               source: data:text/plain;base64,<encoded_base64_string> (2)
             filesystem: root
             mode: 420
             path: /etc/udev/rules.d/41-dasd-eckd-0.0.4444.rules (3)
    1 The role you have defined in the machine config file.
    2 The Base64 encoded string that you have generated in the previous step.
    3 The path where the udev rule is located.

Configuring qeth

The following is an example of how to configure a qeth device by adding a udev rule.

Procedure
  1. Take the following sample udev rule 41-qeth-0.0.1000.rules:

    ACTION=="add", SUBSYSTeM=="drivers", KeRNeL=="qeth", GOTO="group_qeth_0.0.1000"
    ACTION=="add", SUBSYSTeM=="ccw", KeRNeL=="0.0.1000", DRIVeR=="qeth", GOTO="group_qeth_0.0.1000"
    ACTION=="add", SUBSYSTeM=="ccw", KeRNeL=="0.0.1001", DRIVeR=="qeth", GOTO="group_qeth_0.0.1000"
    ACTION=="add", SUBSYSTeM=="ccw", KeRNeL=="0.0.1002", DRIVeR=="qeth", GOTO="group_qeth_0.0.1000"
    ACTION=="add", SUBSYSTeM=="ccwgroup", KeRNeL=="0.0.1000", DRIVeR=="qeth", GOTO="cfg_qeth_0.0.1000"
    GOTO="end_qeth_0.0.1000"
    
    LABeL="group_qeth_0.0.1000"
    TeST=="[ccwgroup/0.0.1000]", GOTO="end_qeth_0.0.1000"
    TeST!="[ccw/0.0.1000]", GOTO="end_qeth_0.0.1000"
    TeST!="[ccw/0.0.1001]", GOTO="end_qeth_0.0.1000"
    TeST!="[ccw/0.0.1002]", GOTO="end_qeth_0.0.1000"
    ATTR{[drivers/ccwgroup:qeth]group}="0.0.1000,0.0.1001,0.0.1002"
    GOTO="end_qeth_0.0.1000"
    
    LABeL="cfg_qeth_0.0.1000"
    ATTR{[ccwgroup/0.0.1000]online}="1"
    
    LABeL="end_qeth_0.0.1000"
  2. Convert the rule to Base64 encoded by running the following command:

    $ base64 /path/to/file/
  3. Copy the following MCO sample profile into a YAML file:

    apiVersion: machineconfiguration.openshift.io/v1
    kind: MachineConfig
    metadata:
       labels:
         machineconfiguration.openshift.io/role: worker0 (1)
       name: 99-worker0-devices
    spec:
       config:
         ignition:
           version: 3.2.0
         storage:
           files:
           - contents:
               source: data:text/plain;base64,<encoded_base64_string> (2)
             filesystem: root
             mode: 420
             path: /etc/udev/rules.d/41-dasd-eckd-0.0.4444.rules (3)
    1 The role you have defined in the machine config file.
    2 The Base64 encoded string that you have generated in the previous step.
    3 The path where the udev rule is located.

Configuring additional devices manually

Tasks in this section describe how to manually configure additional devices in an IBM Z or LinuxONe environment. This configuration method is persistent over node restarts but not OpenShift Container Platform native and you need to redo the steps if you replace the node.

Prerequisites
  • You are logged in to the cluster as a user with administrative privileges.

  • The device must be available to the node.

  • In a z/VM environment, the device must be attached to the z/VM guest.

Procedure
  1. Connect to the node via SSH by running the following command:

    $ ssh <user>@<node_ip_address>

    You can also start a debug session to the node by running the following command:

    $ oc debug node/<node_name>
  2. To enable the devices with the chzdev command, enter the following command:

    $ sudo chzdev -e 0.0.8000
      sudo chzdev -e 1000-1002
      sude chzdev -e 4444
      sudo chzdev -e 0.0.8000:0x500507680d760026:0x00bc000000000000
Additional resources

See Persistent device configuration in IBM Documentation.

RoCe network Cards

RoCe (RDMA over Converged ethernet) network cards do not need to be enabled and their interfaces can be configured with the Kubernetes NMState Operator whenever they are available in the node. For example, RoCe network cards are available if they are attached in a z/VM environment or passed through in a RHeL KVM environment.

enabling multipathing for FCP LUNs

Tasks in this section describe how to manually configure additional devices in an IBM Z or LinuxONe environment. This configuration method is persistent over node restarts but not OpenShift Container Platform native and you need to redo the steps if you replace the node.

On IBM Z and LinuxONe, you can enable multipathing only if you configured your cluster for it during installation. For more information, see "Installing RHCOS and starting the OpenShift Container Platform bootstrap process" in Installing a cluster with z/VM on IBM Z and LinuxONe.

Prerequisites
  • You are logged in to the cluster as a user with administrative privileges.

  • You have configured multiple paths to a LUN with either method explained above.

Procedure
  1. Connect to the node via SSH by running the following command:

    $ ssh <user>@<node_ip_address>

    You can also start a debug session to the node by running the following command:

    $ oc debug node/<node_name>
  2. To enable multipathing, run the following command:

    $ sudo /sbin/mpathconf --enable
  3. To start the multipathd daemon, run the following command:

    $ sudo multipath
  4. Optional: To format your multipath device with fdisk, run the following command:

    $ sudo fdisk /dev/mapper/mpatha
Verification
  • To verify that the devices have been grouped, run the following command:

    $ sudo multipath -II
    example output
    mpatha (20017380030290197) dm-1 IBM,2810XIV
       size=512G features='1 queue_if_no_path' hwhandler='1 alua' wp=rw
    	-+- policy='service-time 0' prio=50 status=enabled
     	|- 1:0:0:6  sde 68:16  active ready running
     	|- 1:0:1:6  sdf 69:24  active ready running
     	|- 0:0:0:6  sdg  8:80  active ready running
     	`- 0:0:1:6  sdh 66:48  active ready running