This is a cache of https://docs.openshift.com/container-platform/4.11/networking/using-ptp.html. It is a snapshot of the page at 2024-11-27T14:10:47.143+0000.
Using PTP hardware | Networking | OpenShift Container Platform 4.11
×

About PTP hardware

You can use the OpenShift Container Platform console or OpenShift CLI (oc) to install PTP by deploying the PTP Operator. The PTP Operator creates and manages the linuxptp services and provides the following features:

  • Discovery of the PTP-capable devices in the cluster.

  • Management of the configuration of linuxptp services.

  • Notification of PTP clock events that negatively affect the performance and reliability of your application with the PTP Operator cloud-event-proxy sidecar.

The PTP Operator works with PTP-capable devices on clusters provisioned only on bare-metal infrastructure.

About PTP

Precision Time Protocol (PTP) is used to synchronize clocks in a network. When used in conjunction with hardware support, PTP is capable of sub-microsecond accuracy, and is more accurate than Network Time Protocol (NTP).

The linuxptp package includes the ptp4l and phc2sys programs for clock synchronization. ptp4l implements the PTP boundary clock and ordinary clock. ptp4l synchronizes the PTP hardware clock to the source clock with hardware time stamping and synchronizes the system clock to the source clock with software time stamping. phc2sys is used for hardware time stamping to synchronize the system clock to the PTP hardware clock on the network interface controller (NIC).

Elements of a PTP domain

PTP is used to synchronize multiple nodes connected in a network, with clocks for each node. The clocks synchronized by PTP are organized in a source-destination hierarchy. The hierarchy is created and updated automatically by the best master clock (BMC) algorithm, which runs on every clock. Destination clocks are synchronized to source clocks, and destination clocks can themselves be the source for other downstream clocks. The following types of clocks can be included in configurations:

Grandmaster clock

The grandmaster clock provides standard time information to other clocks across the network and ensures accurate and stable synchronisation. It writes time stamps and responds to time requests from other clocks. Grandmaster clocks can be synchronized to a Global Positioning System (GPS) time source.

Ordinary clock

The ordinary clock has a single port connection that can play the role of source or destination clock, depending on its position in the network. The ordinary clock can read and write time stamps.

Boundary clock

The boundary clock has ports in two or more communication paths and can be a source and a destination to other destination clocks at the same time. The boundary clock works as a destination clock upstream. The destination clock receives the timing message, adjusts for delay, and then creates a new source time signal to pass down the network. The boundary clock produces a new timing packet that is still correctly synced with the source clock and can reduce the number of connected devices reporting directly to the source clock.

Advantages of PTP over NTP

One of the main advantages that PTP has over NTP is the hardware support present in various network interface controllers (NIC) and network switches. The specialized hardware allows PTP to account for delays in message transfer and improves the accuracy of time synchronization. To achieve the best possible accuracy, it is recommended that all networking components between PTP clocks are PTP hardware enabled.

Hardware-based PTP provides optimal accuracy, since the NIC can time stamp the PTP packets at the exact moment they are sent and received. Compare this to software-based PTP, which requires additional processing of the PTP packets by the operating system.

Before enabling PTP, ensure that NTP is disabled for the required nodes. You can disable the chrony time service (chronyd) using a MachineConfig custom resource. For more information, see Disabling chrony time service.

Using PTP with dual NIC hardware

OpenShift Container Platform supports single and dual NIC hardware for precision PTP timing in the cluster.

For 5G telco networks that deliver mid-band spectrum coverage, each virtual distributed unit (vDU) requires connections to 6 radio units (RUs). To make these connections, each vDU host requires 2 NICs configured as boundary clocks.

Dual NIC hardware allows you to connect each NIC to the same upstream leader clock with separate ptp4l instances for each NIC feeding the downstream clocks.

Installing the PTP Operator using the CLI

As a cluster administrator, you can install the Operator by using the CLI.

Prerequisites
  • A cluster installed on bare-metal hardware with nodes that have hardware that supports PTP.

  • Install the OpenShift CLI (oc).

  • Log in as a user with cluster-admin privileges.

Procedure
  1. Create a namespace for the PTP Operator.

    1. Save the following YAML in the ptp-namespace.yaml file:

      apiVersion: v1
      kind: Namespace
      metadata:
        name: openshift-ptp
        annotations:
          workload.openshift.io/allowed: management
        labels:
          name: openshift-ptp
          openshift.io/cluster-monitoring: "true"
    2. Create the Namespace CR:

      $ oc create -f ptp-namespace.yaml
  2. Create an Operator group for the PTP Operator.

    1. Save the following YAML in the ptp-operatorgroup.yaml file:

      apiVersion: operators.coreos.com/v1
      kind: OperatorGroup
      metadata:
        name: ptp-operators
        namespace: openshift-ptp
      spec:
        targetNamespaces:
        - openshift-ptp
    2. Create the OperatorGroup CR:

      $ oc create -f ptp-operatorgroup.yaml
  3. Subscribe to the PTP Operator.

    1. Save the following YAML in the ptp-sub.yaml file:

      apiVersion: operators.coreos.com/v1alpha1
      kind: Subscription
      metadata:
        name: ptp-operator-subscription
        namespace: openshift-ptp
      spec:
        channel: "stable"
        name: ptp-operator
        source: redhat-operators
        sourceNamespace: openshift-marketplace
    2. Create the Subscription CR:

      $ oc create -f ptp-sub.yaml
  4. To verify that the Operator is installed, enter the following command:

    $ oc get csv -n openshift-ptp -o custom-columns=Name:.metadata.name,Phase:.status.phase
    Example output
    Name                         Phase
    4.12.0-202301261535          Succeeded

Installing the PTP Operator using the web console

As a cluster administrator, you can install the PTP Operator using the web console.

You have to create the namespace and Operator group as mentioned in the previous section.

Procedure
  1. Install the PTP Operator using the OpenShift Container Platform web console:

    1. In the OpenShift Container Platform web console, click OperatorsOperatorHub.

    2. Choose PTP Operator from the list of available Operators, and then click Install.

    3. On the Install Operator page, under A specific namespace on the cluster select openshift-ptp. Then, click Install.

  2. Optional: Verify that the PTP Operator installed successfully:

    1. Switch to the OperatorsInstalled Operators page.

    2. Ensure that PTP Operator is listed in the openshift-ptp project with a Status of InstallSucceeded.

      During installation an Operator might display a Failed status. If the installation later succeeds with an InstallSucceeded message, you can ignore the Failed message.

      If the Operator does not appear as installed, to troubleshoot further:

      • Go to the OperatorsInstalled Operators page and inspect the Operator Subscriptions and Install Plans tabs for any failure or errors under Status.

      • Go to the WorkloadsPods page and check the logs for pods in the openshift-ptp project.

Configuring PTP devices

The PTP Operator adds the NodePtpDevice.ptp.openshift.io custom resource definition (CRD) to OpenShift Container Platform.

When installed, the PTP Operator searches your cluster for PTP-capable network devices on each node. It creates and updates a NodePtpDevice custom resource (CR) object for each node that provides a compatible PTP-capable network device.

Discovering PTP capable network devices in your cluster

  • To return a complete list of PTP capable network devices in your cluster, run the following command:

    $ oc get NodePtpDevice -n openshift-ptp -o yaml
    Example output
    apiVersion: v1
    items:
    - apiVersion: ptp.openshift.io/v1
      kind: NodePtpDevice
      metadata:
        creationTimestamp: "2022-01-27T15:16:28Z"
        generation: 1
        name: dev-worker-0 (1)
        namespace: openshift-ptp
        resourceVersion: "6538103"
        uid: d42fc9ad-bcbf-4590-b6d8-b676c642781a
      spec: {}
      status:
        devices: (2)
        - name: eno1
        - name: eno2
        - name: eno3
        - name: eno4
        - name: enp5s0f0
        - name: enp5s0f1
    ...
    1 The value for the name parameter is the same as the name of the parent node.
    2 The devices collection includes a list of the PTP capable devices that the PTP Operator discovers for the node.

Configuring linuxptp services as a grandmaster clock

You can configure the linuxptp services (ptp4l, phc2sys, ts2phc) as grandmaster clock by creating a PtpConfig custom resource (CR) that configures the host NIC.

The ts2phc utility allows you to synchronize the system clock with the PTP grandmaster clock so that the node can stream precision clock signal to downstream PTP ordinary clocks and boundary clocks.

Use the following example PtpConfig CR as the basis to configure linuxptp services as the grandmaster clock for your particular hardware and environment. This example CR does not configure PTP fast events. To configure PTP fast events, set appropriate values for ptp4lOpts, ptp4lConf, and ptpClockThreshold. ptpClockThreshold is used only when events are enabled. See "Configuring the PTP fast event notifications publisher" for more information.

Prerequisites
  • Install an Intel Westport Channel network interface in the bare-metal cluster host.

  • Install the OpenShift CLI (oc).

  • Log in as a user with cluster-admin privileges.

  • Install the PTP Operator.

Procedure
  1. Create the PtpConfig resource. For example:

    1. Save the following YAML in the grandmaster-clock-ptp-config.yaml file:

      Example PTP grandmaster clock configuration
      apiVersion: ptp.openshift.io/v1
      kind: PtpConfig
      metadata:
        name: grandmaster-clock
        namespace: openshift-ptp
        annotations: {}
      spec:
        profile:
          - name: grandmaster-clock
            # The interface name is hardware-specific
            interface: $interface
            ptp4lOpts: "-2"
            phc2sysOpts: "-a -r -r -n 24"
            ptpSchedulingPolicy: SCHED_FIFO
            ptpSchedulingPriority: 10
            ptpSettings:
              logReduce: "true"
            ptp4lConf: |
              [global]
              #
              # Default Data Set
              #
              twoStepFlag 1
              slaveOnly 0
              priority1 128
              priority2 128
              domainNumber 24
              #utc_offset 37
              clockClass 255
              clockAccuracy 0xFE
              offsetScaledLogVariance 0xFFFF
              free_running 0
              freq_est_interval 1
              dscp_event 0
              dscp_general 0
              dataset_comparison G.8275.x
              G.8275.defaultDS.localPriority 128
              #
              # Port Data Set
              #
              logAnnounceInterval -3
              logSyncInterval -4
              logMinDelayReqInterval -4
              logMinPdelayReqInterval -4
              announceReceiptTimeout 3
              syncReceiptTimeout 0
              delayAsymmetry 0
              fault_reset_interval -4
              neighborPropDelayThresh 20000000
              masterOnly 0
              G.8275.portDS.localPriority 128
              #
              # Run time options
              #
              assume_two_step 0
              logging_level 6
              path_trace_enabled 0
              follow_up_info 0
              hybrid_e2e 0
              inhibit_multicast_service 0
              net_sync_monitor 0
              tc_spanning_tree 0
              tx_timestamp_timeout 50
              unicast_listen 0
              unicast_master_table 0
              unicast_req_duration 3600
              use_syslog 1
              verbose 0
              summary_interval 0
              kernel_leap 1
              check_fup_sync 0
              clock_class_threshold 7
              #
              # Servo Options
              #
              pi_proportional_const 0.0
              pi_integral_const 0.0
              pi_proportional_scale 0.0
              pi_proportional_exponent -0.3
              pi_proportional_norm_max 0.7
              pi_integral_scale 0.0
              pi_integral_exponent 0.4
              pi_integral_norm_max 0.3
              step_threshold 2.0
              first_step_threshold 0.00002
              max_frequency 900000000
              clock_servo pi
              sanity_freq_limit 200000000
              ntpshm_segment 0
              #
              # Transport options
              #
              transportSpecific 0x0
              ptp_dst_mac 01:1B:19:00:00:00
              p2p_dst_mac 01:80:C2:00:00:0E
              udp_ttl 1
              udp6_scope 0x0E
              uds_address /var/run/ptp4l
              #
              # Default interface options
              #
              clock_type OC
              network_transport L2
              delay_mechanism E2E
              time_stamping hardware
              tsproc_mode filter
              delay_filter moving_median
              delay_filter_length 10
              egressLatency 0
              ingressLatency 0
              boundary_clock_jbod 0
              #
              # Clock description
              #
              productDescription ;;
              revisionData ;;
              manufacturerIdentity 00:00:00
              userDescription ;
              timeSource 0xA0
        recommend:
          - profile: grandmaster-clock
            priority: 4
            match:
              - nodeLabel: "node-role.kubernetes.io/$mcp"
    2. Create the CR by running the following command:

      $ oc create -f grandmaster-clock-ptp-config.yaml
Verification
  1. Check that the PtpConfig profile is applied to the node.

    1. Get the list of pods in the openshift-ptp namespace by running the following command:

      $ oc get pods -n openshift-ptp -o wide
      Example output
      NAME                          READY   STATUS    RESTARTS   AGE     IP             NODE
      linuxptp-daemon-74m2g         3/3     Running   3          4d15h   10.16.230.7    compute-1.example.com
      ptp-operator-5f4f48d7c-x7zkf  1/1     Running   1          4d15h   10.128.1.145   compute-1.example.com
    2. Check that the profile is correct. Examine the logs of the linuxptp daemon that corresponds to the node you specified in the PtpConfig profile. Run the following command:

      $ oc logs linuxptp-daemon-74m2g -n openshift-ptp -c linuxptp-daemon-container
      Example output
      ts2phc[94980.334]: [ts2phc.0.config] nmea delay: 98690975 ns
      ts2phc[94980.334]: [ts2phc.0.config] ens3f0 extts index 0 at 1676577329.999999999 corr 0 src 1676577330.901342528 diff -1
      ts2phc[94980.334]: [ts2phc.0.config] ens3f0 master offset         -1 s2 freq      -1
      ts2phc[94980.441]: [ts2phc.0.config] nmea sentence: GNRMC,195453.00,A,4233.24427,N,07126.64420,W,0.008,,160223,,,A,V
      phc2sys[94980.450]: [ptp4l.0.config] CLOCK_REALTIME phc offset       943 s2 freq  -89604 delay    504
      phc2sys[94980.512]: [ptp4l.0.config] CLOCK_REALTIME phc offset      1000 s2 freq  -89264 delay    474

Configuring linuxptp services as an ordinary clock

You can configure linuxptp services (ptp4l, phc2sys) as ordinary clock by creating a PtpConfig custom resource (CR) object.

Use the following example PtpConfig CR as the basis to configure linuxptp services as an ordinary clock for your particular hardware and environment. This example CR does not configure PTP fast events. To configure PTP fast events, set appropriate values for ptp4lOpts, ptp4lConf, and ptpClockThreshold. ptpClockThreshold is required only when events are enabled. See "Configuring the PTP fast event notifications publisher" for more information.

Prerequisites
  • Install the OpenShift CLI (oc).

  • Log in as a user with cluster-admin privileges.

  • Install the PTP Operator.

Procedure
  1. Create the following PtpConfig CR, and then save the YAML in the ordinary-clock-ptp-config.yaml file.

    Example PTP ordinary clock configuration
    apiVersion: ptp.openshift.io/v1
    kind: PtpConfig
    metadata:
      name: ordinary-clock
      namespace: openshift-ptp
      annotations: {}
    spec:
      profile:
        - name: ordinary-clock
          # The interface name is hardware-specific
          interface: $interface
          ptp4lOpts: "-2 -s"
          phc2sysOpts: "-a -r -n 24"
          ptpSchedulingPolicy: SCHED_FIFO
          ptpSchedulingPriority: 10
          ptpSettings:
            logReduce: "true"
          ptp4lConf: |
            [global]
            #
            # Default Data Set
            #
            twoStepFlag 1
            slaveOnly 1
            priority1 128
            priority2 128
            domainNumber 24
            #utc_offset 37
            clockClass 255
            clockAccuracy 0xFE
            offsetScaledLogVariance 0xFFFF
            free_running 0
            freq_est_interval 1
            dscp_event 0
            dscp_general 0
            dataset_comparison G.8275.x
            G.8275.defaultDS.localPriority 128
            #
            # Port Data Set
            #
            logAnnounceInterval -3
            logSyncInterval -4
            logMinDelayReqInterval -4
            logMinPdelayReqInterval -4
            announceReceiptTimeout 3
            syncReceiptTimeout 0
            delayAsymmetry 0
            fault_reset_interval -4
            neighborPropDelayThresh 20000000
            masterOnly 0
            G.8275.portDS.localPriority 128
            #
            # Run time options
            #
            assume_two_step 0
            logging_level 6
            path_trace_enabled 0
            follow_up_info 0
            hybrid_e2e 0
            inhibit_multicast_service 0
            net_sync_monitor 0
            tc_spanning_tree 0
            tx_timestamp_timeout 50
            unicast_listen 0
            unicast_master_table 0
            unicast_req_duration 3600
            use_syslog 1
            verbose 0
            summary_interval 0
            kernel_leap 1
            check_fup_sync 0
            clock_class_threshold 7
            #
            # Servo Options
            #
            pi_proportional_const 0.0
            pi_integral_const 0.0
            pi_proportional_scale 0.0
            pi_proportional_exponent -0.3
            pi_proportional_norm_max 0.7
            pi_integral_scale 0.0
            pi_integral_exponent 0.4
            pi_integral_norm_max 0.3
            step_threshold 2.0
            first_step_threshold 0.00002
            max_frequency 900000000
            clock_servo pi
            sanity_freq_limit 200000000
            ntpshm_segment 0
            #
            # Transport options
            #
            transportSpecific 0x0
            ptp_dst_mac 01:1B:19:00:00:00
            p2p_dst_mac 01:80:C2:00:00:0E
            udp_ttl 1
            udp6_scope 0x0E
            uds_address /var/run/ptp4l
            #
            # Default interface options
            #
            clock_type OC
            network_transport L2
            delay_mechanism E2E
            time_stamping hardware
            tsproc_mode filter
            delay_filter moving_median
            delay_filter_length 10
            egressLatency 0
            ingressLatency 0
            boundary_clock_jbod 0
            #
            # Clock description
            #
            productDescription ;;
            revisionData ;;
            manufacturerIdentity 00:00:00
            userDescription ;
            timeSource 0xA0
      recommend:
        - profile: ordinary-clock
          priority: 4
          match:
            - nodeLabel: "node-role.kubernetes.io/$mcp"
    Table 1. PTP ordinary clock CR configuration options
    Custom resource field Description

    name

    The name of the PtpConfig CR.

    profile

    Specify an array of one or more profile objects. Each profile must be uniquely named.

    interface

    Specify the network interface to be used by the ptp4l service, for example ens787f1.

    ptp4lOpts

    Specify system config options for the ptp4l service, for example -2 to select the IEEE 802.3 network transport. The options should not include the network interface name -i <interface> and service config file -f /etc/ptp4l.conf because the network interface name and the service config file are automatically appended. Append --summary_interval -4 to use PTP fast events with this interface.

    phc2sysOpts

    Specify system config options for the phc2sys service. If this field is empty, the PTP Operator does not start the phc2sys service. For Intel Columbiaville 800 Series NICs, set phc2sysOpts options to -a -r -m -n 24 -N 8 -R 16. -m prints messages to stdout. The linuxptp-daemon DaemonSet parses the logs and generates Prometheus metrics.

    ptp4lConf

    Specify a string that contains the configuration to replace the default /etc/ptp4l.conf file. To use the default configuration, leave the field empty.

    tx_timestamp_timeout

    For Intel Columbiaville 800 Series NICs, set tx_timestamp_timeout to 50.

    boundary_clock_jbod

    For Intel Columbiaville 800 Series NICs, set boundary_clock_jbod to 0.

    ptpSchedulingPolicy

    Scheduling policy for ptp4l and phc2sys processes. Default value is SCHED_OTHER. Use SCHED_FIFO on systems that support FIFO scheduling.

    ptpSchedulingPriority

    Integer value from 1-65 used to set FIFO priority for ptp4l and phc2sys processes when ptpSchedulingPolicy is set to SCHED_FIFO. The ptpSchedulingPriority field is not used when ptpSchedulingPolicy is set to SCHED_OTHER.

    ptpClockThreshold

    Optional. If ptpClockThreshold is not present, default values are used for the ptpClockThreshold fields. ptpClockThreshold configures how long after the PTP master clock is disconnected before PTP events are triggered. holdOverTimeout is the time value in seconds before the PTP clock event state changes to FREERUN when the PTP master clock is disconnected. The maxOffsetThreshold and minOffsetThreshold settings configure offset values in nanoseconds that compare against the values for CLOCK_REALTIME (phc2sys) or master offset (ptp4l). When the ptp4l or phc2sys offset value is outside this range, the PTP clock state is set to FREERUN. When the offset value is within this range, the PTP clock state is set to LOCKED.

    recommend

    Specify an array of one or more recommend objects that define rules on how the profile should be applied to nodes.

    .recommend.profile

    Specify the .recommend.profile object name defined in the profile section.

    .recommend.priority

    Set .recommend.priority to 0 for ordinary clock.

    .recommend.match

    Specify .recommend.match rules with nodeLabel or nodeName values.

    .recommend.match.nodeLabel

    Set nodeLabel with the key of the node.Labels field from the node object by using the oc get nodes --show-labels command. For example, node-role.kubernetes.io/worker.

    .recommend.match.nodeName

    Set nodeName with the value of the node.Name field from the node object by using the oc get nodes command. For example, compute-1.example.com.

  2. Create the PtpConfig CR by running the following command:

    $ oc create -f ordinary-clock-ptp-config.yaml
Verification
  1. Check that the PtpConfig profile is applied to the node.

    1. Get the list of pods in the openshift-ptp namespace by running the following command:

      $ oc get pods -n openshift-ptp -o wide
      Example output
      NAME                            READY   STATUS    RESTARTS   AGE   IP               NODE
      linuxptp-daemon-4xkbb           1/1     Running   0          43m   10.1.196.24      compute-0.example.com
      linuxptp-daemon-tdspf           1/1     Running   0          43m   10.1.196.25      compute-1.example.com
      ptp-operator-657bbb64c8-2f8sj   1/1     Running   0          43m   10.129.0.61      control-plane-1.example.com
    2. Check that the profile is correct. Examine the logs of the linuxptp daemon that corresponds to the node you specified in the PtpConfig profile. Run the following command:

      $ oc logs linuxptp-daemon-4xkbb -n openshift-ptp -c linuxptp-daemon-container
      Example output
      I1115 09:41:17.117596 4143292 daemon.go:107] in applyNodePTPProfile
      I1115 09:41:17.117604 4143292 daemon.go:109] updating NodePTPProfile to:
      I1115 09:41:17.117607 4143292 daemon.go:110] ------------------------------------
      I1115 09:41:17.117612 4143292 daemon.go:102] Profile Name: profile1
      I1115 09:41:17.117616 4143292 daemon.go:102] Interface: ens787f1
      I1115 09:41:17.117620 4143292 daemon.go:102] Ptp4lOpts: -2 -s
      I1115 09:41:17.117623 4143292 daemon.go:102] Phc2sysOpts: -a -r -n 24
      I1115 09:41:17.117626 4143292 daemon.go:116] ------------------------------------
Additional resources

Configuring linuxptp services as a boundary clock

You can configure the linuxptp services (ptp4l, phc2sys) as boundary clock by creating a PtpConfig custom resource (CR) object.

Use the following example PtpConfig CR as the basis to configure linuxptp services as the boundary clock for your particular hardware and environment. This example CR does not configure PTP fast events. To configure PTP fast events, set appropriate values for ptp4lOpts, ptp4lConf, and ptpClockThreshold. ptpClockThreshold is used only when events are enabled. See "Configuring the PTP fast event notifications publisher" for more information.

Prerequisites
  • Install the OpenShift CLI (oc).

  • Log in as a user with cluster-admin privileges.

  • Install the PTP Operator.

Procedure
  1. Create the following PtpConfig CR, and then save the YAML in the boundary-clock-ptp-config.yaml file.

    Example PTP boundary clock configuration
    apiVersion: ptp.openshift.io/v1
    kind: PtpConfig
    metadata:
      name: boundary-clock
      namespace: openshift-ptp
      annotations: {}
    spec:
      profile:
        - name: boundary-clock
          ptp4lOpts: "-2"
          phc2sysOpts: "-a -r -n 24"
          ptpSchedulingPolicy: SCHED_FIFO
          ptpSchedulingPriority: 10
          ptpSettings:
            logReduce: "true"
          ptp4lConf: |
            # The interface name is hardware-specific
            [$iface_slave]
            masterOnly 0
            [$iface_master_1]
            masterOnly 1
            [$iface_master_2]
            masterOnly 1
            [$iface_master_3]
            masterOnly 1
            [global]
            #
            # Default Data Set
            #
            twoStepFlag 1
            slaveOnly 0
            priority1 128
            priority2 128
            domainNumber 24
            #utc_offset 37
            clockClass 248
            clockAccuracy 0xFE
            offsetScaledLogVariance 0xFFFF
            free_running 0
            freq_est_interval 1
            dscp_event 0
            dscp_general 0
            dataset_comparison G.8275.x
            G.8275.defaultDS.localPriority 128
            #
            # Port Data Set
            #
            logAnnounceInterval -3
            logSyncInterval -4
            logMinDelayReqInterval -4
            logMinPdelayReqInterval -4
            announceReceiptTimeout 3
            syncReceiptTimeout 0
            delayAsymmetry 0
            fault_reset_interval -4
            neighborPropDelayThresh 20000000
            masterOnly 0
            G.8275.portDS.localPriority 128
            #
            # Run time options
            #
            assume_two_step 0
            logging_level 6
            path_trace_enabled 0
            follow_up_info 0
            hybrid_e2e 0
            inhibit_multicast_service 0
            net_sync_monitor 0
            tc_spanning_tree 0
            tx_timestamp_timeout 50
            unicast_listen 0
            unicast_master_table 0
            unicast_req_duration 3600
            use_syslog 1
            verbose 0
            summary_interval 0
            kernel_leap 1
            check_fup_sync 0
            clock_class_threshold 135
            #
            # Servo Options
            #
            pi_proportional_const 0.0
            pi_integral_const 0.0
            pi_proportional_scale 0.0
            pi_proportional_exponent -0.3
            pi_proportional_norm_max 0.7
            pi_integral_scale 0.0
            pi_integral_exponent 0.4
            pi_integral_norm_max 0.3
            step_threshold 2.0
            first_step_threshold 0.00002
            max_frequency 900000000
            clock_servo pi
            sanity_freq_limit 200000000
            ntpshm_segment 0
            #
            # Transport options
            #
            transportSpecific 0x0
            ptp_dst_mac 01:1B:19:00:00:00
            p2p_dst_mac 01:80:C2:00:00:0E
            udp_ttl 1
            udp6_scope 0x0E
            uds_address /var/run/ptp4l
            #
            # Default interface options
            #
            clock_type BC
            network_transport L2
            delay_mechanism E2E
            time_stamping hardware
            tsproc_mode filter
            delay_filter moving_median
            delay_filter_length 10
            egressLatency 0
            ingressLatency 0
            boundary_clock_jbod 0
            #
            # Clock description
            #
            productDescription ;;
            revisionData ;;
            manufacturerIdentity 00:00:00
            userDescription ;
            timeSource 0xA0
      recommend:
        - profile: boundary-clock
          priority: 4
          match:
            - nodeLabel: "node-role.kubernetes.io/$mcp"
    Table 2. PTP boundary clock CR configuration options
    Custom resource field Description

    name

    The name of the PtpConfig CR.

    profile

    Specify an array of one or more profile objects.

    name

    Specify the name of a profile object which uniquely identifies a profile object.

    ptp4lOpts

    Specify system config options for the ptp4l service. The options should not include the network interface name -i <interface> and service config file -f /etc/ptp4l.conf because the network interface name and the service config file are automatically appended.

    ptp4lConf

    Specify the required configuration to start ptp4l as boundary clock. For example, ens1f0 synchronizes from a grandmaster clock and ens1f3 synchronizes connected devices.

    <interface_1>

    The interface that receives the synchronization clock.

    <interface_2>

    The interface that sends the synchronization clock.

    tx_timestamp_timeout

    For Intel Columbiaville 800 Series NICs, set tx_timestamp_timeout to 50.

    boundary_clock_jbod

    For Intel Columbiaville 800 Series NICs, ensure boundary_clock_jbod is set to 0. For Intel Fortville X710 Series NICs, ensure boundary_clock_jbod is set to 1.

    phc2sysOpts

    Specify system config options for the phc2sys service. If this field is empty, the PTP Operator does not start the phc2sys service.

    ptpSchedulingPolicy

    Scheduling policy for ptp4l and phc2sys processes. Default value is SCHED_OTHER. Use SCHED_FIFO on systems that support FIFO scheduling.

    ptpSchedulingPriority

    Integer value from 1-65 used to set FIFO priority for ptp4l and phc2sys processes when ptpSchedulingPolicy is set to SCHED_FIFO. The ptpSchedulingPriority field is not used when ptpSchedulingPolicy is set to SCHED_OTHER.

    ptpClockThreshold

    Optional. If ptpClockThreshold is not present, default values are used for the ptpClockThreshold fields. ptpClockThreshold configures how long after the PTP master clock is disconnected before PTP events are triggered. holdOverTimeout is the time value in seconds before the PTP clock event state changes to FREERUN when the PTP master clock is disconnected. The maxOffsetThreshold and minOffsetThreshold settings configure offset values in nanoseconds that compare against the values for CLOCK_REALTIME (phc2sys) or master offset (ptp4l). When the ptp4l or phc2sys offset value is outside this range, the PTP clock state is set to FREERUN. When the offset value is within this range, the PTP clock state is set to LOCKED.

    recommend

    Specify an array of one or more recommend objects that define rules on how the profile should be applied to nodes.

    .recommend.profile

    Specify the .recommend.profile object name defined in the profile section.

    .recommend.priority

    Specify the priority with an integer value between 0 and 99. A larger number gets lower priority, so a priority of 99 is lower than a priority of 10. If a node can be matched with multiple profiles according to rules defined in the match field, the profile with the higher priority is applied to that node.

    .recommend.match

    Specify .recommend.match rules with nodeLabel or nodeName values.

    .recommend.match.nodeLabel

    Set nodeLabel with the key of the node.Labels field from the node object by using the oc get nodes --show-labels command. For example, node-role.kubernetes.io/worker.

    .recommend.match.nodeName

    Set nodeName with the value of the node.Name field from the node object by using the oc get nodes command. For example, compute-1.example.com.

  2. Create the CR by running the following command:

    $ oc create -f boundary-clock-ptp-config.yaml
Verification
  1. Check that the PtpConfig profile is applied to the node.

    1. Get the list of pods in the openshift-ptp namespace by running the following command:

      $ oc get pods -n openshift-ptp -o wide
      Example output
      NAME                            READY   STATUS    RESTARTS   AGE   IP               NODE
      linuxptp-daemon-4xkbb           1/1     Running   0          43m   10.1.196.24      compute-0.example.com
      linuxptp-daemon-tdspf           1/1     Running   0          43m   10.1.196.25      compute-1.example.com
      ptp-operator-657bbb64c8-2f8sj   1/1     Running   0          43m   10.129.0.61      control-plane-1.example.com
    2. Check that the profile is correct. Examine the logs of the linuxptp daemon that corresponds to the node you specified in the PtpConfig profile. Run the following command:

      $ oc logs linuxptp-daemon-4xkbb -n openshift-ptp -c linuxptp-daemon-container
      Example output
      I1115 09:41:17.117596 4143292 daemon.go:107] in applyNodePTPProfile
      I1115 09:41:17.117604 4143292 daemon.go:109] updating NodePTPProfile to:
      I1115 09:41:17.117607 4143292 daemon.go:110] ------------------------------------
      I1115 09:41:17.117612 4143292 daemon.go:102] Profile Name: profile1
      I1115 09:41:17.117616 4143292 daemon.go:102] Interface:
      I1115 09:41:17.117620 4143292 daemon.go:102] Ptp4lOpts: -2
      I1115 09:41:17.117623 4143292 daemon.go:102] Phc2sysOpts: -a -r -n 24
      I1115 09:41:17.117626 4143292 daemon.go:116] ------------------------------------
Additional resources

Configuring linuxptp services as boundary clocks for dual NIC hardware

Precision Time Protocol (PTP) hardware with dual NIC configured as boundary clocks is a Technology Preview feature only. Technology Preview features are not supported with Red Hat production service level agreements (SLAs) and might not be functionally complete. Red Hat does not recommend using them in production. These features provide early access to upcoming product features, enabling customers to test functionality and provide feedback during the development process.

For more information about the support scope of Red Hat Technology Preview features, see Technology Preview Features Support Scope.

You can configure the linuxptp services (ptp4l, phc2sys) as boundary clocks for dual NIC hardware by creating a PtpConfig custom resource (CR) object for each NIC.

Dual NIC hardware allows you to connect each NIC to the same upstream leader clock with separate ptp4l instances for each NIC feeding the downstream clocks.

Prerequisites
  • Install the OpenShift CLI (oc).

  • Log in as a user with cluster-admin privileges.

  • Install the PTP Operator.

Procedure
  1. Create two separate PtpConfig CRs, one for each NIC, using the reference CR in "Configuring linuxptp services as a boundary clock" as the basis for each CR. For example:

    1. Create boundary-clock-ptp-config-nic1.yaml, specifying values for phc2sysOpts:

      apiVersion: ptp.openshift.io/v1
      kind: PtpConfig
      metadata:
        name: boundary-clock-ptp-config-nic1
        namespace: openshift-ptp
      spec:
        profile:
        - name: "profile1"
          ptp4lOpts: "-2 --summary_interval -4"
          ptp4lConf: | (1)
            [ens5f1]
            masterOnly 1
            [ens5f0]
            masterOnly 0
          ...
          phc2sysOpts: "-a -r -m -n 24 -N 8 -R 16" (2)
      1 Specify the required interfaces to start ptp4l as a boundary clock. For example, ens5f0 synchronizes from a grandmaster clock and ens5f1 synchronizes connected devices.
      2 Required phc2sysOpts values. -m prints messages to stdout. The linuxptp-daemon DaemonSet parses the logs and generates Prometheus metrics.
    2. Create boundary-clock-ptp-config-nic2.yaml, removing the phc2sysOpts field altogether to disable the phc2sys service for the second NIC:

      apiVersion: ptp.openshift.io/v1
      kind: PtpConfig
      metadata:
        name: boundary-clock-ptp-config-nic2
        namespace: openshift-ptp
      spec:
        profile:
        - name: "profile2"
          ptp4lOpts: "-2 --summary_interval -4"
          ptp4lConf: | (1)
            [ens7f1]
            masterOnly 1
            [ens7f0]
            masterOnly 0
      ...
      1 Specify the required interfaces to start ptp4l as a boundary clock on the second NIC.

      You must completely remove the phc2sysOpts field from the second PtpConfig CR to disable the phc2sys service on the second NIC.

  2. Create the dual NIC PtpConfig CRs by running the following commands:

    1. Create the CR that configures PTP for the first NIC:

      $ oc create -f boundary-clock-ptp-config-nic1.yaml
    2. Create the CR that configures PTP for the second NIC:

      $ oc create -f boundary-clock-ptp-config-nic2.yaml
Verification
  • Check that the PTP Operator has applied the PtpConfig CRs for both NICs. Examine the logs for the linuxptp daemon corresponding to the node that has the dual NIC hardware installed. For example, run the following command:

    $ oc logs linuxptp-daemon-cvgr6 -n openshift-ptp -c linuxptp-daemon-container
    Example output
    ptp4l[80828.335]: [ptp4l.1.config] master offset          5 s2 freq   -5727 path delay       519
    ptp4l[80828.343]: [ptp4l.0.config] master offset         -5 s2 freq  -10607 path delay       533
    phc2sys[80828.390]: [ptp4l.0.config] CLOCK_REALTIME phc offset         1 s2 freq  -87239 delay    539

Intel Columbiaville E800 series NIC as PTP ordinary clock reference

The following table describes the changes that you must make to the reference PTP configuration in order to use Intel Columbiaville E800 series NICs as ordinary clocks. Make the changes in a PtpConfig custom resource (CR) that you apply to the cluster.

Table 3. Recommended PTP settings for Intel Columbiaville NIC
PTP configuration Recommended setting

phc2sysOpts

-a -r -m -n 24 -N 8 -R 16

tx_timestamp_timeout

50

boundary_clock_jbod

0

For phc2sysOpts, -m prints messages to stdout. The linuxptp-daemon DaemonSet parses the logs and generates Prometheus metrics.

Additional resources

Configuring FIFO priority scheduling for PTP hardware

In telco or other deployment configurations that require low latency performance, PTP daemon threads run in a constrained CPU footprint alongside the rest of the infrastructure components. By default, PTP threads run with the SCHED_OTHER policy. Under high load, these threads might not get the scheduling latency they require for error-free operation.

To mitigate against potential scheduling latency errors, you can configure the PTP Operator linuxptp services to allow threads to run with a SCHED_FIFO policy. If SCHED_FIFO is set for a PtpConfig CR, then ptp4l and phc2sys will run in the parent container under chrt with a priority set by the ptpSchedulingPriority field of the PtpConfig CR.

Setting ptpSchedulingPolicy is optional, and is only required if you are experiencing latency errors.

Procedure
  1. Edit the PtpConfig CR profile:

    $ oc edit PtpConfig -n openshift-ptp
  2. Change the ptpSchedulingPolicy and ptpSchedulingPriority fields:

    apiVersion: ptp.openshift.io/v1
    kind: PtpConfig
    metadata:
      name: <ptp_config_name>
      namespace: openshift-ptp
    ...
    spec:
      profile:
      - name: "profile1"
    ...
        ptpSchedulingPolicy: SCHED_FIFO (1)
        ptpSchedulingPriority: 10 (2)
    1 Scheduling policy for ptp4l and phc2sys processes. Use SCHED_FIFO on systems that support FIFO scheduling.
    2 Required. Sets the integer value 1-65 used to configure FIFO priority for ptp4l and phc2sys processes.
  3. Save and exit to apply the changes to the PtpConfig CR.

Verification
  1. Get the name of the linuxptp-daemon pod and corresponding node where the PtpConfig CR has been applied:

    $ oc get pods -n openshift-ptp -o wide
    Example output
    NAME                            READY   STATUS    RESTARTS   AGE     IP            NODE
    linuxptp-daemon-gmv2n           3/3     Running   0          1d17h   10.1.196.24   compute-0.example.com
    linuxptp-daemon-lgm55           3/3     Running   0          1d17h   10.1.196.25   compute-1.example.com
    ptp-operator-3r4dcvf7f4-zndk7   1/1     Running   0          1d7h    10.129.0.61   control-plane-1.example.com
  2. Check that the ptp4l process is running with the updated chrt FIFO priority:

    $ oc -n openshift-ptp logs linuxptp-daemon-lgm55 -c linuxptp-daemon-container|grep chrt
    Example output
    I1216 19:24:57.091872 1600715 daemon.go:285] /bin/chrt -f 65 /usr/sbin/ptp4l -f /var/run/ptp4l.0.config -2  --summary_interval -4 -m

Troubleshooting common PTP Operator issues

Troubleshoot common problems with the PTP Operator by performing the following steps.

Prerequisites
  • Install the OpenShift Container Platform CLI (oc).

  • Log in as a user with cluster-admin privileges.

  • Install the PTP Operator on a bare-metal cluster with hosts that support PTP.

Procedure
  1. Check the Operator and operands are successfully deployed in the cluster for the configured nodes.

    $ oc get pods -n openshift-ptp -o wide
    Example output
    NAME                            READY   STATUS    RESTARTS   AGE     IP            NODE
    linuxptp-daemon-lmvgn           3/3     Running   0          4d17h   10.1.196.24   compute-0.example.com
    linuxptp-daemon-qhfg7           3/3     Running   0          4d17h   10.1.196.25   compute-1.example.com
    ptp-operator-6b8dcbf7f4-zndk7   1/1     Running   0          5d7h    10.129.0.61   control-plane-1.example.com

    When the PTP fast event bus is enabled, the number of ready linuxptp-daemon pods is 3/3. If the PTP fast event bus is not enabled, 2/2 is displayed.

  2. Check that supported hardware is found in the cluster.

    $ oc -n openshift-ptp get nodeptpdevices.ptp.openshift.io
    Example output
    NAME                                  AGE
    control-plane-0.example.com           10d
    control-plane-1.example.com           10d
    compute-0.example.com                 10d
    compute-1.example.com                 10d
    compute-2.example.com                 10d
  3. Check the available PTP network interfaces for a node:

    $ oc -n openshift-ptp get nodeptpdevices.ptp.openshift.io <node_name> -o yaml

    where:

    <node_name>

    Specifies the node you want to query, for example, compute-0.example.com.

    Example output
    apiVersion: ptp.openshift.io/v1
    kind: NodePtpDevice
    metadata:
      creationTimestamp: "2021-09-14T16:52:33Z"
      generation: 1
      name: compute-0.example.com
      namespace: openshift-ptp
      resourceVersion: "177400"
      uid: 30413db0-4d8d-46da-9bef-737bacd548fd
    spec: {}
    status:
      devices:
      - name: eno1
      - name: eno2
      - name: eno3
      - name: eno4
      - name: enp5s0f0
      - name: enp5s0f1
  4. Check that the PTP interface is successfully synchronized to the primary clock by accessing the linuxptp-daemon pod for the corresponding node.

    1. Get the name of the linuxptp-daemon pod and corresponding node you want to troubleshoot by running the following command:

      $ oc get pods -n openshift-ptp -o wide
      Example output
      NAME                            READY   STATUS    RESTARTS   AGE     IP            NODE
      linuxptp-daemon-lmvgn           3/3     Running   0          4d17h   10.1.196.24   compute-0.example.com
      linuxptp-daemon-qhfg7           3/3     Running   0          4d17h   10.1.196.25   compute-1.example.com
      ptp-operator-6b8dcbf7f4-zndk7   1/1     Running   0          5d7h    10.129.0.61   control-plane-1.example.com
    2. Remote shell into the required linuxptp-daemon container:

      $ oc rsh -n openshift-ptp -c linuxptp-daemon-container <linux_daemon_container>

      where:

      <linux_daemon_container>

      is the container you want to diagnose, for example linuxptp-daemon-lmvgn.

    3. In the remote shell connection to the linuxptp-daemon container, use the PTP Management Client (pmc) tool to diagnose the network interface. Run the following pmc command to check the sync status of the PTP device, for example ptp4l.

      # pmc -u -f /var/run/ptp4l.0.config -b 0 'GET PORT_DATA_SET'
      Example output when the node is successfully synced to the primary clock
      sending: GET PORT_DATA_SET
          40a6b7.fffe.166ef0-1 seq 0 RESPONSE MANAGEMENT PORT_DATA_SET
              portIdentity            40a6b7.fffe.166ef0-1
              portState               SLAVE
              logMinDelayReqInterval  -4
              peerMeanPathDelay       0
              logAnnounceInterval     -3
              announceReceiptTimeout  3
              logSyncInterval         -4
              delayMechanism          1
              logMinPdelayReqInterval -4
              versionNumber           2

Collecting Precision Time Protocol (PTP) Operator data

You can use the oc adm must-gather CLI command to collect information about your cluster, including features and objects associated with Precision Time Protocol (PTP) Operator.

Prerequisites
  • You have access to the cluster as a user with the cluster-admin role.

  • You have installed the OpenShift CLI (oc).

  • You have installed the PTP Operator.

Procedure
  • To collect PTP Operator data with must-gather, you must specify the PTP Operator must-gather image.

    $ oc adm must-gather --image=registry.redhat.io/openshift4/ptp-must-gather-rhel8:v4.11

PTP hardware fast event notifications framework

About PTP and clock synchronization error events

Cloud native applications such as virtual RAN require access to notifications about hardware timing events that are critical to the functioning of the overall network. Fast event notifications are early warning signals about impending and real-time Precision Time Protocol (PTP) clock synchronization events. PTP clock synchronization errors can negatively affect the performance and reliability of your low latency application, for example, a vRAN application running in a distributed unit (DU).

Loss of PTP synchronization is a critical error for a RAN network. If synchronization is lost on a node, the radio might be shut down and the network Over the Air (OTA) traffic might be shifted to another node in the wireless network. Fast event notifications mitigate against workload errors by allowing cluster nodes to communicate PTP clock sync status to the vRAN application running in the DU.

Event notifications are available to RAN applications running on the same DU node. A publish/subscribe REST API passes events notifications to the messaging bus. Publish/subscribe messaging, or pub/sub messaging, is an asynchronous service to service communication architecture where any message published to a topic is immediately received by all the subscribers to the topic.

Fast event notifications are generated by the PTP Operator in OpenShift Container Platform for every PTP-capable network interface. The events are made available using a cloud-event-proxy sidecar container over an Advanced Message Queuing Protocol (AMQP) message bus. The AMQP message bus is provided by the AMQ Interconnect Operator.

PTP fast event notifications are available for network interfaces configured to use PTP ordinary clocks or PTP boundary clocks.

About the PTP fast event notifications framework

You can subscribe distributed unit (DU) applications to Precision Time Protocol (PTP) fast events notifications that are generated by OpenShift Container Platform with the PTP Operator and cloud-event-proxy sidecar container. You enable the cloud-event-proxy sidecar container by setting the enableEventPublisher field to true in the ptpOperatorConfig custom resource (CR) and specifying an Advanced Message Queuing Protocol (AMQP) transportHost address. PTP fast events use an AMQP event notification bus provided by the AMQ Interconnect Operator. AMQ Interconnect is a component of Red Hat AMQ, a messaging router that provides flexible routing of messages between any AMQP-enabled endpoints. An overview of the PTP fast events framework is below:

Overview of PTP fast events
Figure 1. Overview of PTP fast events

The cloud-event-proxy sidecar container can access the same resources as the primary vRAN application without using any of the resources of the primary application and with no significant latency.

The fast events notifications framework uses a REST API for communication and is based on the O-RAN REST API specification. The framework consists of a publisher, subscriber, and an AMQ messaging bus to handle communications between the publisher and subscriber applications. The cloud-event-proxy sidecar is a utility container that runs in a pod that is loosely coupled to the main DU application container on the DU node. It provides an event publishing framework that allows you to subscribe DU applications to published PTP events.

DU applications run the cloud-event-proxy container in a sidecar pattern to subscribe to PTP events. The following workflow describes how a DU application uses PTP fast events:

  1. DU application requests a subscription: The DU sends an API request to the cloud-event-proxy sidecar to create a PTP events subscription. The cloud-event-proxy sidecar creates a subscription resource.

  2. cloud-event-proxy sidecar creates the subscription: The event resource is persisted by the cloud-event-proxy sidecar. The cloud-event-proxy sidecar container sends an acknowledgment with an ID and URL location to access the stored subscription resource. The sidecar creates an AMQ messaging listener protocol for the resource specified in the subscription.

  3. DU application receives the PTP event notification: The cloud-event-proxy sidecar container listens to the address specified in the resource qualifier. The DU events consumer processes the message and passes it to the return URL specified in the subscription.

  4. cloud-event-proxy sidecar validates the PTP event and posts it to the DU application: The cloud-event-proxy sidecar receives the event, unwraps the cloud events object to retrieve the data, and fetches the return URL to post the event back to the DU consumer application.

  5. DU application uses the PTP event: The DU application events consumer receives and processes the PTP event.

Installing the AMQ messaging bus

To pass PTP fast event notifications between publisher and subscriber on a node, you must install and configure an AMQ messaging bus to run locally on the node. You do this by installing the AMQ Interconnect Operator for use in the cluster.

Prerequisites
  • Install the OpenShift Container Platform CLI (oc).

  • Log in as a user with cluster-admin privileges.

Procedure
Verification
  1. Check that the AMQ Interconnect Operator is available and the required pods are running:

    $ oc get pods -n amq-interconnect
    Example output
    NAME                                    READY   STATUS    RESTARTS   AGE
    amq-interconnect-645db76c76-k8ghs       1/1     Running   0          23h
    interconnect-operator-5cb5fc7cc-4v7qm   1/1     Running   0          23h
  2. Check that the required linuxptp-daemon PTP event producer pods are running in the openshift-ptp namespace.

    $ oc get pods -n openshift-ptp
    Example output
    NAME                     READY   STATUS    RESTARTS       AGE
    linuxptp-daemon-2t78p    3/3     Running   0              12h
    linuxptp-daemon-k8n88    3/3     Running   0              12h

Configuring the PTP fast event notifications publisher

To start using PTP fast event notifications for a network interface in your cluster, you must enable the fast event publisher in the PTP Operator PtpOperatorConfig custom resource (CR) and configure ptpClockThreshold values in a PtpConfig CR that you create.

Prerequisites
  • Install the OpenShift Container Platform CLI (oc).

  • Log in as a user with cluster-admin privileges.

  • Install the PTP Operator and AMQ Interconnect Operator.

Procedure
  1. Modify the default PTP Operator config to enable PTP fast events.

    1. Save the following YAML in the ptp-operatorconfig.yaml file:

      apiVersion: ptp.openshift.io/v1
      kind: PtpOperatorConfig
      metadata:
        name: default
        namespace: openshift-ptp
      spec:
        daemonNodeSelector:
          node-role.kubernetes.io/worker: ""
        ptpEventConfig:
          enableEventPublisher: true (1)
          transportHost: amqp://<instance_name>.<namespace>.svc.cluster.local (2)
      1 Set enableEventPublisher to true to enable PTP fast event notifications.
      2 Set transportHost to the AMQ router that you configured where <instance_name> and <namespace> correspond to the AMQ Interconnect router instance name and namespace, for example, amqp://amq-interconnect.amq-interconnect.svc.cluster.local
    2. Update the PtpOperatorConfig CR:

      $ oc apply -f ptp-operatorconfig.yaml
  2. Create a PtpConfig custom resource (CR) for the PTP enabled interface, and set the required values for ptpClockThreshold and ptp4lOpts. The following YAML illustrates the required values that you must set in the PtpConfig CR:

    spec:
      profile:
      - name: "profile1"
        interface: "enp5s0f0"
        ptp4lOpts: "-2 -s --summary_interval -4" (1)
        phc2sysOpts: "-a -r -m -n 24 -N 8 -R 16" (2)
        ptp4lConf: "" (3)
        ptpClockThreshold: (4)
          holdOverTimeout: 5
          maxOffsetThreshold: 100
          minOffsetThreshold: -100
    1 Append --summary_interval -4 to use PTP fast events.
    2 Required phc2sysOpts values. -m prints messages to stdout. The linuxptp-daemon DaemonSet parses the logs and generates Prometheus metrics.
    3 Specify a string that contains the configuration to replace the default /etc/ptp4l.conf file. To use the default configuration, leave the field empty.
    4 Optional. If the ptpClockThreshold stanza is not present, default values are used for the ptpClockThreshold fields. The stanza shows default ptpClockThreshold values. The ptpClockThreshold values configure how long after the PTP master clock is disconnected before PTP events are triggered. holdOverTimeout is the time value in seconds before the PTP clock event state changes to FREERUN when the PTP master clock is disconnected. The maxOffsetThreshold and minOffsetThreshold settings configure offset values in nanoseconds that compare against the values for CLOCK_REALTIME (phc2sys) or master offset (ptp4l). When the ptp4l or phc2sys offset value is outside this range, the PTP clock state is set to FREERUN. When the offset value is within this range, the PTP clock state is set to LOCKED.
Additional resources

Subscribing DU applications to PTP events REST API reference

Use the PTP event notifications REST API to subscribe a distributed unit (DU) application to the PTP events that are generated on the parent node.

Subscribe applications to PTP events by using the resource address /cluster/node/<node_name>/ptp, where <node_name> is the cluster node running the DU application.

Deploy your cloud-event-consumer DU application container and cloud-event-proxy sidecar container in a separate DU application pod. The cloud-event-consumer DU application subscribes to the cloud-event-proxy container in the application pod.

Use the following API endpoints to subscribe the cloud-event-consumer DU application to PTP events posted by the cloud-event-proxy container at http://localhost:8089/api/ocloudNotifications/v1/ in the DU application pod:

  • /api/ocloudNotifications/v1/subscriptions

    • POST: Creates a new subscription

    • GET: Retrieves a list of subscriptions

  • /api/ocloudNotifications/v1/subscriptions/<subscription_id>

    • GET: Returns details for the specified subscription ID

  • /api/ocloudNotifications/v1/health

    • GET: Returns the health status of ocloudNotifications API

  • api/ocloudNotifications/v1/publishers

    • GET: Returns an array of os-clock-sync-state, ptp-clock-class-change, and lock-state messages for the cluster node

  • /api/ocloudnotifications/v1/<resource_address>/CurrentState

    • GET: Returns the current state of one the following event types: os-clock-sync-state, ptp-clock-class-change, or lock-state events

9089 is the default port for the cloud-event-consumer container deployed in the application pod. You can configure a different port for your DU application as required.

api/ocloudNotifications/v1/subscriptions

HTTP method

GET api/ocloudNotifications/v1/subscriptions

Description

Returns a list of subscriptions. If subscriptions exist, a 200 OK status code is returned along with the list of subscriptions.

Example API response
[
 {
  "id": "75b1ad8f-c807-4c23-acf5-56f4b7ee3826",
  "endpointUri": "http://localhost:9089/event",
  "uriLocation": "http://localhost:8089/api/ocloudNotifications/v1/subscriptions/75b1ad8f-c807-4c23-acf5-56f4b7ee3826",
  "resource": "/cluster/node/compute-1.example.com/ptp"
 }
]
HTTP method

POST api/ocloudNotifications/v1/subscriptions

Description

Creates a new subscription. If a subscription is successfully created, or if it already exists, a 201 Created status code is returned.

Table 4. Query parameters
Parameter Type

subscription

data

Example payload
{
  "uriLocation": "http://localhost:8089/api/ocloudNotifications/v1/subscriptions",
  "resource": "/cluster/node/compute-1.example.com/ptp"
}

api/ocloudNotifications/v1/subscriptions/<subscription_id>

HTTP method

GET api/ocloudNotifications/v1/subscriptions/<subscription_id>

Description

Returns details for the subscription with ID <subscription_id>

Table 5. Query parameters
Parameter Type

<subscription_id>

string

Example API response
{
  "id":"48210fb3-45be-4ce0-aa9b-41a0e58730ab",
  "endpointUri": "http://localhost:9089/event",
  "uriLocation":"http://localhost:8089/api/ocloudNotifications/v1/subscriptions/48210fb3-45be-4ce0-aa9b-41a0e58730ab",
  "resource":"/cluster/node/compute-1.example.com/ptp"
}

api/ocloudNotifications/v1/health/

HTTP method

GET api/ocloudNotifications/v1/health/

Description

Returns the health status for the ocloudNotifications REST API.

Example API response
OK

api/ocloudNotifications/v1/publishers

HTTP method

GET api/ocloudNotifications/v1/publishers

Description

Returns an array of os-clock-sync-state, ptp-clock-class-change, and lock-state details for the cluster node. The system generates notifications when the relevant equipment state changes.

  • os-clock-sync-state notifications describe the host operating system clock synchronization state. Can be in LOCKED or FREERUN state.

  • ptp-clock-class-change notifications describe the current state of the PTP clock class.

  • lock-state notifications describe the current status of the PTP equipment lock state. Can be in LOCKED, HOLDOVER or FREERUN state.

Example API response
[
  {
    "id": "0fa415ae-a3cf-4299-876a-589438bacf75",
    "endpointUri": "http://localhost:9085/api/ocloudNotifications/v1/dummy",
    "uriLocation": "http://localhost:9085/api/ocloudNotifications/v1/publishers/0fa415ae-a3cf-4299-876a-589438bacf75",
    "resource": "/cluster/node/compute-1.example.com/sync/sync-status/os-clock-sync-state"
  },
  {
    "id": "28cd82df-8436-4f50-bbd9-7a9742828a71",
    "endpointUri": "http://localhost:9085/api/ocloudNotifications/v1/dummy",
    "uriLocation": "http://localhost:9085/api/ocloudNotifications/v1/publishers/28cd82df-8436-4f50-bbd9-7a9742828a71",
    "resource": "/cluster/node/compute-1.example.com/sync/ptp-status/ptp-clock-class-change"
  },
  {
    "id": "44aa480d-7347-48b0-a5b0-e0af01fa9677",
    "endpointUri": "http://localhost:9085/api/ocloudNotifications/v1/dummy",
    "uriLocation": "http://localhost:9085/api/ocloudNotifications/v1/publishers/44aa480d-7347-48b0-a5b0-e0af01fa9677",
    "resource": "/cluster/node/compute-1.example.com/sync/ptp-status/lock-state"
  }
]

You can find os-clock-sync-state, ptp-clock-class-change and lock-state events in the logs for the cloud-event-proxy container. For example:

$ oc logs -f linuxptp-daemon-cvgr6 -n openshift-ptp -c cloud-event-proxy
Example os-clock-sync-state event
{
   "id":"c8a784d1-5f4a-4c16-9a81-a3b4313affe5",
   "type":"event.sync.sync-status.os-clock-sync-state-change",
   "source":"/cluster/compute-1.example.com/ptp/CLOCK_REALTIME",
   "dataContentType":"application/json",
   "time":"2022-05-06T15:31:23.906277159Z",
   "data":{
      "version":"v1",
      "values":[
         {
            "resource":"/sync/sync-status/os-clock-sync-state",
            "dataType":"notification",
            "valueType":"enumeration",
            "value":"LOCKED"
         },
         {
            "resource":"/sync/sync-status/os-clock-sync-state",
            "dataType":"metric",
            "valueType":"decimal64.3",
            "value":"-53"
         }
      ]
   }
}
Example ptp-clock-class-change event
{
   "id":"69eddb52-1650-4e56-b325-86d44688d02b",
   "type":"event.sync.ptp-status.ptp-clock-class-change",
   "source":"/cluster/compute-1.example.com/ptp/ens2fx/master",
   "dataContentType":"application/json",
   "time":"2022-05-06T15:31:23.147100033Z",
   "data":{
      "version":"v1",
      "values":[
         {
            "resource":"/sync/ptp-status/ptp-clock-class-change",
            "dataType":"metric",
            "valueType":"decimal64.3",
            "value":"135"
         }
      ]
   }
}
Example lock-state event
{
   "id":"305ec18b-1472-47b3-aadd-8f37933249a9",
   "type":"event.sync.ptp-status.ptp-state-change",
   "source":"/cluster/compute-1.example.com/ptp/ens2fx/master",
   "dataContentType":"application/json",
   "time":"2022-05-06T15:31:23.467684081Z",
   "data":{
      "version":"v1",
      "values":[
         {
            "resource":"/sync/ptp-status/lock-state",
            "dataType":"notification",
            "valueType":"enumeration",
            "value":"LOCKED"
         },
         {
            "resource":"/sync/ptp-status/lock-state",
            "dataType":"metric",
            "valueType":"decimal64.3",
            "value":"62"
         }
      ]
   }
}

/api/ocloudnotifications/v1/<resource_address>/CurrentState

HTTP method

GET api/ocloudNotifications/v1/cluster/node/<node_name>/sync/ptp-status/lock-state/CurrentState

GET api/ocloudNotifications/v1/cluster/node/<node_name>/sync/sync-status/os-clock-sync-state/CurrentState

GET api/ocloudNotifications/v1/cluster/node/<node_name>/sync/ptp-status/ptp-clock-class-change/CurrentState

Description

Configure the CurrentState API endpoint to return the current state of the os-clock-sync-state, ptp-clock-class-change, or lock-state events for the cluster node.

  • os-clock-sync-state notifications describe the host operating system clock synchronization state. Can be in LOCKED or FREERUN state.

  • ptp-clock-class-change notifications describe the current state of the PTP clock class.

  • lock-state notifications describe the current status of the PTP equipment lock state. Can be in LOCKED, HOLDOVER or FREERUN state.

Table 6. Query parameters
Parameter Type

<resource_address>

string

Example lock-state API response
{
  "id": "c1ac3aa5-1195-4786-84f8-da0ea4462921",
  "type": "event.sync.ptp-status.ptp-state-change",
  "source": "/cluster/node/compute-1.example.com/sync/ptp-status/lock-state",
  "dataContentType": "application/json",
  "time": "2023-01-10T02:41:57.094981478Z",
  "data": {
    "version": "v1",
    "values": [
      {
        "resource": "/cluster/node/compute-1.example.com/ens5fx/master",
        "dataType": "notification",
        "valueType": "enumeration",
        "value": "LOCKED"
      },
      {
        "resource": "/cluster/node/compute-1.example.com/ens5fx/master",
        "dataType": "metric",
        "valueType": "decimal64.3",
        "value": "29"
      }
    ]
  }
}
Example os-clock-sync-state API response
{
  "specversion": "0.3",
  "id": "4f51fe99-feaa-4e66-9112-66c5c9b9afcb",
  "source": "/cluster/node/compute-1.example.com/sync/sync-status/os-clock-sync-state",
  "type": "event.sync.sync-status.os-clock-sync-state-change",
  "subject": "/cluster/node/compute-1.example.com/sync/sync-status/os-clock-sync-state",
  "datacontenttype": "application/json",
  "time": "2022-11-29T17:44:22.202Z",
  "data": {
    "version": "v1",
    "values": [
      {
        "resource": "/cluster/node/compute-1.example.com/CLOCK_REALTIME",
        "dataType": "notification",
        "valueType": "enumeration",
        "value": "LOCKED"
      },
      {
        "resource": "/cluster/node/compute-1.example.com/CLOCK_REALTIME",
        "dataType": "metric",
        "valueType": "decimal64.3",
        "value": "27"
      }
    ]
  }
}
Example ptp-clock-class-change API response
{
  "id": "064c9e67-5ad4-4afb-98ff-189c6aa9c205",
  "type": "event.sync.ptp-status.ptp-clock-class-change",
  "source": "/cluster/node/compute-1.example.com/sync/ptp-status/ptp-clock-class-change",
  "dataContentType": "application/json",
  "time": "2023-01-10T02:41:56.785673989Z",
  "data": {
    "version": "v1",
    "values": [
      {
        "resource": "/cluster/node/compute-1.example.com/ens5fx/master",
        "dataType": "metric",
        "valueType": "decimal64.3",
        "value": "165"
      }
    ]
  }
}

Monitoring PTP fast event metrics using the CLI

You can monitor fast events bus metrics directly from cloud-event-proxy containers using the oc CLI.

PTP fast event notification metrics are also available in the OpenShift Container Platform web console.

Prerequisites
  • Install the OpenShift Container Platform CLI (oc).

  • Log in as a user with cluster-admin privileges.

  • Install and configure the PTP Operator.

Procedure
  1. Get the list of active linuxptp-daemon pods.

    $ oc get pods -n openshift-ptp
    Example output
    NAME                    READY   STATUS    RESTARTS   AGE
    linuxptp-daemon-2t78p   3/3     Running   0          8h
    linuxptp-daemon-k8n88   3/3     Running   0          8h
  2. Access the metrics for the required cloud-event-proxy container by running the following command:

    $ oc exec -it <linuxptp-daemon> -n openshift-ptp -c cloud-event-proxy -- curl 127.0.0.1:9091/metrics

    where:

    <linuxptp-daemon>

    Specifies the pod you want to query, for example, linuxptp-daemon-2t78p.

    Example output
    # HELP cne_amqp_events_published Metric to get number of events published by the transport
    # TYPE cne_amqp_events_published gauge
    cne_amqp_events_published{address="/cluster/node/compute-1.example.com/ptp/status",status="success"} 1041
    # HELP cne_amqp_events_received Metric to get number of events received  by the transport
    # TYPE cne_amqp_events_received gauge
    cne_amqp_events_received{address="/cluster/node/compute-1.example.com/ptp",status="success"} 1019
    # HELP cne_amqp_receiver Metric to get number of receiver created
    # TYPE cne_amqp_receiver gauge
    cne_amqp_receiver{address="/cluster/node/mock",status="active"} 1
    cne_amqp_receiver{address="/cluster/node/compute-1.example.com/ptp",status="active"} 1
    cne_amqp_receiver{address="/cluster/node/compute-1.example.com/redfish/event",status="active"}
    ...

Monitoring PTP fast event metrics in the web console

You can monitor PTP fast event metrics in the OpenShift Container Platform web console by using the pre-configured and self-updating Prometheus monitoring stack.

Prerequisites
  • Install the OpenShift Container Platform CLI oc.

  • Log in as a user with cluster-admin privileges.

Procedure
  1. Enter the following command to return the list of available PTP metrics from the cloud-event-proxy sidecar container:

    $ oc exec -it <linuxptp_daemon_pod> -n openshift-ptp -c cloud-event-proxy -- curl 127.0.0.1:9091/metrics

    where:

    <linuxptp_daemon_pod>

    Specifies the pod you want to query, for example, linuxptp-daemon-2t78p.

  2. Copy the name of the PTP metric you want to query from the list of returned metrics, for example, cne_amqp_events_received.

  3. In the OpenShift Container Platform web console, click ObserveMetrics.

  4. Paste the PTP metric into the Expression field, and click Run queries.

Additional resources