kubeletArguments: pods-per-core: - "10"
In addition to pod traffic, the most-used data-path in an OpenShift Container Platform infrastructure is between the OpenShift Container Platform master hosts and etcd. The OpenShift Container Platform API server (part of the master binary) consults etcd for node status, network configuration, secrets, and more.
Optimize this traffic path by:
Co-locating master hosts and etcd servers.
Ensuring an uncongested, low latency LAN communication link between master hosts.
The OpenShift Container Platform node configuration file at /etc/origin/node/node-config.yaml contains important options, such as the iptables synchronization period, the Maximum Transmission Unit (MTU) of the SDN network, and the proxy-mode.
The node configuration file allows you to pass arguments to the kubelet
(node) process. You can view a list of possible options by running kubelet
--help
.
Not all kubelet options are supported by OpenShift Container Platform, and are used in the upstream Kubernetes. This means certain options are in limited support. |
In the /etc/origin/node/node-config.yaml file, two parameters control the
maximum number of pods that can be scheduled to a node: pods-per-core
and
max-pods
. When both options are in use, the lower of the two limits the number
of pods on a node. Exceeding these values can result in:
Increased CPU utilization on both OpenShift Container Platform and Docker.
Slow pod scheduling.
Potential out-of-memory scenarios (depends on the amount of memory in the node).
Exhausting the pool of IP addresses.
Resource overcommitting, leading to poor user application performance.
In Kubernetes, a pod that is holding a single container actually uses two containers. The second container is used to set up networking prior to the actual container starting. Therefore, a system running 10 pods will actually have 20 containers running. |
pods-per-core
sets the number of pods the node can run based on the number of
processor cores on the node. For example, if pods-per-core
is set to 10
on
a node with 4 processor cores, the maximum number of pods allowed on the node
will be 40.
kubeletArguments: pods-per-core: - "10"
Setting |
max-pods
sets the number of pods the node can run to a fixed value, regardless
of the properties of the node.
kubeletArguments: max-pods: - "250"
Using the above example, the default value for pods-per-core
is 10
and the
default value for max-pods
is 250
. This means that unless the node has 25
cores or more, by default, pods-per-core
will be the limiting factor.
See the Sizing Considerations section in the installation documentation for the recommended limits for an OpenShift Container Platform cluster. The recommended sizing accounts for OpenShift Container Platform and Docker coordination for container status updates. This coordination puts CPU pressure on the master and docker processes, which can include writing a large amount of log data.
etcd is a distributed key-value store that OpenShift Container Platform uses for configuration.
OpenShift Container Platform Version |
etcd version |
storage schema version |
3.3 and earlier |
2.x |
v2 |
3.4 and 3.5 |
3.x |
v2 |
3.6 |
3.x |
v2 (upgrades) |
3.6 |
3.x |
v3 (new installations) |
etcd 3.x introduces important scalability and performance improvements that reduce CPU, memory, network, and disk requirements for any size cluster. etcd 3.x also implements a backwards compatible storage API that facilitates a two-step migration of the on-disk etcd database. For migration purposes, the storage mode used by etcd 3.x in OpenShift Container Platform 3.5 remained in v2 mode. As of OpenShift Container Platform 3.6, new installs will use storage mode v3. Upgrades from previous versions of OpenShift Container Platform will not automatically migrate data from v2 to v3. You must use the supplied playbooks and follow the documented process to migrate the data.
Version 3 of etcd implements a backwards compatible storage API that facilitates a two-step migration of the on-disk etcd database. For migration purposes, the storage mode used by etcd 3.x in OpenShift Container Platform 3.5 remained in v2 mode. As of OpenShift Container Platform 3.6, new installs will use storage mode v3. In order to provide customers time to prepare for migrating the etcd schema from v2 to v3 (and associated downtime and verification), OpenShift Container Platform 3.6 does not enforce this upgrade. However, based on extensive test results Red Hat strongly recommends migrating existing OpenShift Container Platform clusters to etcd 3.x storage mode v3. This is particularly relevant in larger clusters, or in scenarios where SSD storage is not available.
etcd schema migration will be required by future OpenShift Container Platform upgrades. |
In addition to changing the storage mode for new installs to v3, OpenShift Container Platform 3.6 also begins enforcing quorum reads for all OpenShift Container Platform types. This is done to ensure that queries against etcd do not return stale data. In single-node etcd clusters, stale data is not a concern. In highly available etcd deployments typically found in production clusters, quorum reads ensure valid query results. A quorum read is linearizable in database terms - every client sees the latest updated state of the cluster, and all clients see the same sequence of reads and writes. See the etcd 3.1 announcement for more information on performance improvements.
It is important to note that OpenShift Container Platform uses etcd for storing additional information beyond what Kubernetes itself requires. For example, OpenShift Container Platform stores information about images, builds, and other components in etcd, as is required by features that OpenShift Container Platform adds on top of Kubernetes. Ultimately, this means that guidance around performance and sizing for etcd hosts will differ from Kubernetes and other recommendations in salient ways. Red Hat tests etcd scalability and performance with the OpenShift Container Platform use-case and parameters in mind to generate the most accurate recommendations.
Performance improvements were quantified using a 300-node OpenShift Container Platform 3.6 cluster using the cluster-loader utility. Comparing etcd 3.x (storage mode v2) versus etcd 3.x (storage mode v3), clear improvements are identified in the charts below.
Storage IOPS under load is significantly reduced:
Storage IOPS in steady state is also significantly reduced:
Viewing the same I/O data, plotting the average IOPS in both modes:
CPU utilization by both the API server (master) and etcd processes is reduced:
Memory utilization by both the API server (master) and etcd processes is also reduced:
After profiling etcd under OpenShift Container Platform, etcd frequently performs small amounts of storage input and output. Using etcd with storage that handles small read/write operations quickly, such as SSD, is highly recommended. |
Looking at the size I/O operations done by a 3-node cluster of etcd 3.1 (using storage v3 mode and with quorum reads enforced), read sizes are as follows:
And writes:
etcd processes are typically memory intensive. Master / API server processes are CPU intensive. This makes them a reasonable co-location pair within a single machine or virtual machine (VM). Optimize communication between etcd and master hosts either by co-locating them on the same host, or providing a dedicated network. |
To provide fast storage to an etcd node so that etcd is stable at large scale, use PCI passthrough to pass a non-volatile memory express (NVMe) device directly to the etcd node. To set this up with Red Hat OpenStack 11 or later, complete the following on the OpenStack compute nodes where the PCI device exists.
Ensure Intel Vt-x is enabled in BIOS.
Enable the input–output memory management unit (IOMMU). In the
/etc/sysconfig/grub file, add intel_iommu=on iommu=pt
to the end of the
GRUB_CMDLINX_LINUX
line, within the quotation marks.
Regenerate /etc/grub2.cfg by running:
$ grub2-mkconfig -o /etc/grub2.cfg
Reboot the system.
On controllers in /etc/nova.conf:
[filter_scheduler] enabled_filters=RetryFilter,AvailabilityZoneFilter,RamFilter,DiskFilter,ComputeFilter,ComputeCapabilitiesFilter,ImagePropertiesFilter,ServerGroupAntiAffinityFilter,ServerGroupAffinityFilter,PciPassthroughFilter available_filters=nova.scheduler.filters.all_filters [pci] alias = { "vendor_id":"144d", "product_id":"a820", "device_type":"type-PCI", "name":"nvme" }
Restart nova-api
and nova-scheduler
on the controllers.
On compute nodes in /etc/nova/nova.conf:
[pci] passthrough_whitelist = { "address": "0000:06:00.0" } alias = { "vendor_id":"144d", "product_id":"a820", "device_type":"type-PCI", "name":"nvme" }
To retrieve the required address
, vendor_id
, and product_id
values of the
NVMe device you want to passthrough, run:
# lspci -nn | grep devicename
Restart nova-compute
on the compute nodes.
Configure the OpenStack version you are running to use the NVMe and launch the etcd node.
TuneD is a tuning profile delivery mechanism enabled by default in Red Hat Enterprise Linux and other Red Hat products. TuneD customizes Linux settings, such as sysctls, power management, and kernel command line options, to optimize the operating system for different workload performance and scalability requirements.
OpenShift Container Platform leverages the tuned
daemon and includes TuneD profiles called
atomic-openshift-host
and atomic-openshift-guest
. These profiles safely
increase some of the commonly encountered vertical scaling limits present in the
kernel, and are automatically applied to your system during installation.
The TuneD profiles support inheritance between profiles. On an OpenShift Container Platform
system, the findings delivered by TuneD will be the union of
throughput-performance
(the default for RHEL) and atomic-openshift-guest
.
TuneD will determine if you are running OpenShift Container Platform on a virtual machine,
and, if so, automatically apply virtual-guest
tuning as well.
To see which TuneD profile is enabled on your system, run:
# tuned-adm active Current active profile: atomic-openshift-node-guest
See the Red Hat Enterprise Linux Performance Tuning Guide for more information about TuneD.